OL580 infrared spectrophotometric oil analyzer
USD $5,630 - $5,800 /Set
Min.Order:1 Set
Lixian Instrument Scientific Co., Ltd.
OL580 infrared spectrophotometric oil analyzer
Standards :
National environmental standards“HJ637-2012Water quality determination of stone and animal and vegetable oil by infrared spectrophotometry ”
National standard “GB3838-2002 Surface water environmental quality standard”
National standard “GB18918-2002 Pollutant discharge standard of urban sewage treatment plant”
Application :
Mainly used in the detection of surface water, underground water, industrial waste water, sewage from oil substances.Environmental monitoring systems, traffic environmental monitoring, railway environment monitoring, marine environmental monitoring, agricultural environment monitoring, industrial and mining enterprise environmental monitoring, municipal drainage monitoring, water companies, sewage treatment plant, oil refining, petroleum and petrochemical industry waste water, chemical, steel, metallurgy, hydrology, water conservancy, and thermal power plants, automobile manufacturing, colleges and universities and research institutes and other testing room, laboratory use.
Technical parameters:
Name | OL580 infrared spectrophotometric oil analyzer |
Basic measure range
| 0.15~80.00mg/l(4cm Cuvette,Extract oil concentration) |
Detect limit | DL<0.1mg/l(4cm Cuvette,Extract ) |
Minimum detectable concentration
| 0.0015mg/l(oil concentration in water ) |
Maximum measurement concentration
| 64000mg/l(oil concentration in water ) |
Accuracy error | <±2%(Concentration 30~60mg/mL Standard oil sample) |
Repeatability | RSD<1.5%(concentration is 30~60mg/mL Standard oil sample) |
Linear correlation coefficient | R>0.999 |
Absorbance range | 0.00000~2.00000AU(Transmission rate100~1%T) |
Wave number range | 3400cm-1~2400cm-1(2941nm~4167nm) |
Wave number resolution
| 0.2 cm-1 |
Wave number accuracy | ±2cm-1 |
Wave number repeatability | ±2cm-1 |
Sample analysis time | Full spectrum scan: 30 seconds |
Reference wavelength calibration
| manual control |
Host size | 450mm(L)×320mm(W)×170mm(H) |
Host weight | 14Kg |
Host power
| 220 ± 10% V,50Hz,40W |
External input | RS232port |
Use environment | 5℃~35℃,20%~80%RH |
Technical parameters :
1, Using integrated optical system, the first light absorption, in accord with the characteristics of infrared spectrum, good stability, high signal noise ratio.
2,The electric light source is used to reduce the heating intensity of the light source, and to help the system heat dissipation. At the same time, the structure of the instrument is simplified, and the stability of the instrument is improved.
3, The stepping motor control grating has the function of wavelength correction, high wavelength accuracy and good repeatability.
4, Unique design of the structure of the color pool, 1 to 4 cm in any more than a color dish.
5,The instrument optical system, the electrical system is integrated, and the integrated degree is high, so it can improve the reliability and maintainability of the instrument.
6,The operation is simple, just click the mouse to complete a kind of determination of oil.