EA128 laser dust monitor PM10 PM2.5 PM1.0 TSP
USD $4,500 - $4,800 /Unit
Min.Order:1 Unit
Lixian Instrument Scientific Co., Ltd.
LD-5 laser dust monitor PM10 PM2.5 PM1.0 TSP
Introduction
Using laser dust monitor new built-in filter online sampler LD-5 laser dust monitor has the international advanced level in the new century, with continuous monitoring of dust concentration at the same time, can be collected particles, in order to analyze the composition, and calculate the concentration conversion coefficient K value. Direct reading dust mass concentration (mg/m3) of PM10, PM2.5, PM1.0, and TSP cutter selection. The instrument adopted a strong pump, making it more suitable for the detection of central air conditioning with longer need exhaust sampling cutter selection. The instrument adopted a strong pump, making it more suitable for the detection of central air conditioning with longer need exhaust sampling pipe outlet PM10concentration of inhalable particles, and to monitor inhalable dust PM2.5.
The instrument conforms to the hygienic standard for industrial enterprises (GBZ1-2002), Hazardous agents in the workplace exposure limits (GBZ2-2002) standard, the Ministry of health WS/T206-2001 “public place air of respirable particulate matter (PM10) in public places sanitary specification of centralized air ventilation system is the industry standard method for the determination of light scattering method”, the Ministry of labor standard LD98-1996 “light scattering powder the dust concentration in the air and railway ministry standard Determination Method” TB/T2323-92 “the determination of dust in the air of workplace relative mass concentration and mass concentration conversion method” and the Ministry of health in order No. 225 document issued by the “[2003]”.
Features
1. Design a particle cutter can be replaced, to achieve the PM10, PM5, PM2.5, TSP a variety of particle separation cutting compatible.
2. The design of online filter membrane sampler, realize continuous monitoring of dust concentration and membrane sampling compatible, can analyze the collected particulate matter composition and find out the place of concentration conversion coefficient K value.
3. Using the laser source, concentration conversion factor is not affected by the particle color.
4. The large screen LCD display, Chinese menu is realized.
5. The design of the constant current controller, to ensure that the sampling flow rate is constant, the correct cutting curve.
6. With built-in optical standard spread plate, ensure the high stability of the instrument.
7. Protective gas special scene, to avoid instrument core parts of optical system of dust pollution, ensure the instruments with high reliability.
8. Through the computer software realization of instrument automatic zero adjustment, improves the precision of measuring instruments, is convenient for users to use.
9. Instrument design timing sampling mechanism, according to the set time sampling, from time to time to start and shut down, the results obtained can be used to deal with the data recorded by the micro printer or into the PC machine, and make the instrument suitable for atmospheric particulate matter monitoring environment. The instrument can be set.
10. Alarm threshold of dust dust concentration exceed the standard, exceed the standard automatic alarm, or the signal is transmitted to the control center for monitoring.
11. Design the analog output interface, to evaluate the air purifier, which can draw the purification efficiency evaluation curve.
12. In addition to a suitable indoor public places dust monitoring general measurement mode and timing sampling model for atmospheric environmental monitoring, increase
Labor health mode, in this mode, according to industry hygiene standard (GBZ1-2002) and workplace exposure to harmful factors limit standard (GBZ2-2002), time weighted average (TWA) and the permissible concentration short term exposure (STEL).
Technical Parameters
1. The configuration of 40mm membrane online sampler;
2. Can be replaced with PM10, PM5, particle cutter PM2.5, PM1.0 and TSP options;
3. Direct reading dust mass concentration (fand mg/m), 1 minutes out of the
4. Large screen liquid crystal display, Chinese characters menu prompt;
5. The detection sensitivity: LD 5 (L) 0.01mg/m fand; LD 5 (H) 0.001mg/m fand.
6. The repeatability error: + 2%
7. Accuracy: + 10%
8. Measurement range: LD - 5 (L) of 0.01 ~ 100 mg/m3; LD 5 (H) of 0.001~10 mg/m3.
9. The determination of time: standard time is 1 minutes, with 0.1 points and manual (can be arbitrarily set sampling time).
10. With public monitoring mode, monitoring of atmospheric environment and occupational health mode. Can calculate the time weighted average (TWA) and short time contact allowable concentration (STEL).
11. Storage: cycle store 999 group of data.
12. Sampling time: set the measurement time (1 ~ 9999) seconds, off time (0 ~ 9999) seconds, preheating time (0 ~ 10) seconds and sampling times (1 ~ 9999) time.
13. Dust concentration exceed the standard alarm threshold settings: the maximum concentration threshold: 65mg/m3; Determination of time: (1 ~ 9999).
14. Output interface:
(1) PC communication interface:
RS232 optional optional; RS485; radio communication; optional GPRS
(2) Micro printer output interface;
(3) The analog output interface: 0 1V; the optional 4-20mA
(4) The digital output interface: signal.
15. Power: Ni-MH battery (1.2V x 4), 8 hours of continuous use of 220VAC/12VDC power adapter.
16. Optional humidity correction function, the data is more accurate
17. Weight: 2.4kg. 195mm*85mm*132mm
18. The standard configuration: instrument, battery, power adapter, purses, cutter, screwdriver, membrane, one of five small plastic bag, manual, certificate, warranty
19. Optional: instrument special communication software, micro printer, the sampling rod (send domestic hose), cutter three tripod, standard
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries
Our mission is to make every effort to contribute to all humanity.