ZH1550 Simultaneous Thermal Analyzer
USD $11,000 - $18,600 /Set
Min.Order:1 Set
Lixian Instrument Scientific Co., Ltd.
Introduction:
Comprehensive thermal analysis will heat the TG DTA and differential thermal analysis and differential scanning calorimetry (DSC combined into an organic whole, pain again measurement using the same sample synchronization by TG and DTA and DSC. Comprehensive thermal analysis main measuring physical and chemical changes related to the heat, such as the material of melting point, heat of fusion and crystallization and
crystallization heat, phase change heat of reaction, thermal stability (oxidation induction period), the glass transition temperature, adsorption and desorption, composition of content analysis, decomposition, combination, dehydration, the change such as additives were studied. Flexible design with rich option is your ideal tool in the laboratory. Equipment is widely used in most materials, including plastic, rubber, synthetic resin, fiber, coating, grease ceramics, cement, glass, refractory materials, fuel, medicine, food, refractory materials, etc.
technical features
Rich type, 7 inch touch screen display information, including the set temperature, sample temperature,
DTA, thermogravimetric signals, nitrogen flow, oxygen flow, the information such as all kinds of switch state.
USB communication interface or so communication, strong commonality, reliable communication don't interrupt,
support the restore the connection.
Furnace body structure is compact, elevating temperature rate of arbitrary adjustable
Improved the installation process, all adopt mechanical fixed way, completely avoid the furnace internal colloid to differential thermal, thermal pollution of signals.
Double temperature probe, make sure the height of the sample temperature measurement repeatability. Temperature
sensor installed on the furnace wall, all the way to the PID control of the furnace temperature, but due to the temperature of thermal inertia, conduction to the temperature of the sample on a certain deviation, and deviation degree of chun xiaqiu winter is different, therefore, adopt single temperature probe temperature control and temperature measuring, differential thermal signals and temperature signals, error is large; The
instrument in the samples at the bottom of the installation of a temperature sensor, used to measure the real temperature of the sample, and we use special temperature control technology, control the temperature of furnace wall temperature to reach the set temperature.
Equipped with gas mass flowmeter atmosphere automatic switching network traffic, fast switching and stable time
With standard sample, convenient customer temperature correction coefficient
The software adaptive resolution computer screen, the software automatically according to the computer
display screen size to adjust the curve. Support notebooks, desktops; Support the Win2000, XP, VISTA,
Windows 7 operating system.
Support user programming procedures, the realization of full automatic measuring steps, the software provides
dozens of instructions, the user can according to your own measurement steps, and combined the instruction,
and save. Complex operation is simplified into a key operation. TG and DSC and TG - DTA sample stents, used
in the real synchronous measurement.
Range of application
Widely application and plastic, rubber, synthetic resin, fiber, coating, grease ceramics, cement, glass,
refractory materials, fuel, medicine, food, metal/alloy, minerals, a variety of fields such as catalysts,
including can materials. Study the following characteristics:
DSC; Melting, crystallization, phase change, reaction temperature and reaction heat, heat of combustion, heat...
TG: thermal stability, decomposition, REDOX, adsorption, desorption, free water and crystal water content,
composition calculation.
Technical parameters
DSC Measuring range | ±500mW |
Weight measurement range
| 1mg-1g,If you need large doses can be customized, highest can be extended to 50 g
|
Temperature range | At room temperature - 1550 ℃
|
The temperature accuracy
| ±0.1℃ |
DSC resolution | ±0.01μW |
resolution | 0.1μg |
Heating rate | 0.1℃/mln-100℃/mln Arbitrary adjustable |
Display mode | 7 inch touch screen |
Atmosphere control system
| Use glass rotor flow meter or digital mass flow controller
|
Dear customer,
We ,Xi’an Yima Opto-electrical Technology Com.,Ltd. is an integrated economic entity of R&D,manufacturing and trading with over 20 years of history .
Our business scope covers various fields such as biochemical analysis,environmental protection,industrial testing, bioscience,medical apparatus and instruments,internet technology and some frontier science.
Through a long-time development,we own a national resources system of various professional talents , abundant supply for various components &parts and special materials, full producing &processing equipments , strong Technological standardization and a complete quality assurance system.
If you need OEM or ODM in manufacturing ,scientific research , market development and or you want to build your own brand in your country, it’s our honor to cooperate with you.In this way ,we have developed many products for our customers from the USA, Europe and South Africa and got good feedback on Alibaba
We firmly believe that science and technology is no boundaries
Our mission is to make every effort to contribute to all humanity.