N2XSE(F)Y three cores Copper conductor xlpe insulated copper and tape screened 18/33kv power cable
USD $0.1 - $60 /Meter
Min.Order:500 Meters
Shuanglin Communication Technology Co., Ltd.
N2XSE(F)Y three cores Copper conductor xlpe insulated copper wire and tape screened 18/33kv power cable
WITH UL,TUV,KEMA,CE,BV,PSB,SABA CERTIFICATIONS
WITH TUV TYPE TESTING REPORT
ISO9001,ISO18001,OHSAS18001
Executive Standard:
HRN HD 620 S1
IEC 60502-2
DIN VDE 0276 part 620
Application:
Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability. Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.
Construction:
Conductor: | Cu round conductor, multi wire stranded compacted (RM), class 2 acc. to HRN HD 383 / IEC 60228 / DIN VDE 0295 | |
Inner screen: | extruded semi-conductive skin on conductor | |
Insulation: | XLPE (cross-linked polyethylene, recent mark: PE-X) compound DIX 8 acc. to HRN HD 620 S1 ili 2XI1 acc. to DIN VDE 0207 dio 22 | |
External screen: | extruded semi-conductive skin on insulation, longitudinally spliced with insulation (+tape of semi-conductive material) | |
Concentric conductor: | in inner layer corrugated spirally wrapped copper wires, in external layer copper tape wrapped in counter-helix | |
Filler: | extruded elastomer or plastomer compound | |
Sheath: | PVC compound DMV-6 acc. to HRN HD 620 S1 or YM5 acc. to DIN VDE 0207 part 5 | |
sheath colour: | red |
Dimensions – number of cores x conductor cross-section | Construction | External diameter | External diameter | Conductor diameter | Insulation thickness | Conductor resistance at 20 °C | Short circuit current 1s | Cu weight | Cable weight | Packing* |
min. | max. | max. | nominal | max. | nominal | approx. | ||||
N x mm² | mm | mm | mm | mm | Ω/km | A | kg/km | kg/km | ||
3 x 25/16 | RM | 43 | 3,4 | 0,727 | 3,58 | 1046 | 2850 | CUT | ||
3 x 35/16 | RM | 47 | 51 | 7,5 | 3,4 | 0,524 | 5,01 | 1209 | 3300 | CUT |
3 x 50/16 | RM | 50 | 55 | 8,6 | 3,4 | 0,387 | 7,15 | 1671 | 3900 | CUT |
3 x 70/16 | RM | 53 | 58 | 10,2 | 3,4 | 0,268 | 10,01 | 2247 | 4700 | CUT |
3 x 95/16 | RM | 57 | 62 | 12,0 | 3,4 | 0,193 | 13,59 | 2994 | 5850 | CUT |
3 x 120/16 | RM | 61 | 67 | 13,5 | 3,4 | 0,153 | 17,16 | 3714 | 6800 | CUT |
3 x 150/25 | RM | 64 | 70 | 15,0 | 3,4 | 0,124 | 21,45 | 4638 | 7950 | CUT |
3 x 185/25 | RM | 68 | 74 | 16,8 | 3,4 | 0,0991 | 26,46 | 5646 | 9300 | CUT |
3 x 240/25 | RM | 74 | 80 | 19,2 | 3,4 | 0,0754 | 34,32 | 7272 | 11550 | CUT |
3 x 300/25 | RM | 78 | 90 | 3,4 | 0,0601 | 42,50 | 9160 | 14450 | CUT |
Packing and shipping
Company information: