Multi-parameter Gas Detector
Multi-parameter Gas Detector
Multi-parameter Gas Detector
Multi-parameter Gas Detector
Multi-parameter Gas Detector

Multi-parameter Gas Detector

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
1 Piece / Pieces per Month
Port:
Shanghai
Payment Terms:
T/T

Quick Details View All >

Brand Name:
KY
Place of Origin:
China
Model Number:
CD4

Xuzhou KY Automation Technology Co., Ltd

Business license
Business Type: Manufacturer
Xuzhou Jiangsu China
Main Products: Coal Mining Ventilation Resistance Meter ,Portable Nondestructive Tester for Steel Wire Rope ,Mining Motor Operation Parameter Meter ,Mining Intrinsic Safe Resistance Meter ,Mining Portable Ultrasonic Flowmeter ,Hand-held Ultrasonic Flowmeter ,Laser Range Finder ,Mining Temperature and Humidity Meter ,Multi-Parameter Gas Detector ,Sound Level Meter ,Underground Pipeline Ultrasonic Leak Tester ,Portable Digital Dust Meter

Product Details

Model: CD4

Description: CD4 Multi-parameter Gas Detector

MA: MFA150188 (National safety sign for coal mining products)

KA: KFA150017 (National safety sign for mining products)

ExibI : 320150860 (Intrinsic safe and explosion-proof products certificate)

ExiaII: CMExC17.4385

 

Introduction:

1. Detect the gas concentration of CH4, O2, CO, H2S.

2. 8 digitals micro-controller as control unit, high sensitivity and fast response speed, high precision detecting element.

3. Large LCD screen to ensure high definition display.

4. Detector will cause luminescence and voice alarm if gas concentration is over standard.

 

Technology parameters:


1. CH4:

Measuring range

Error expected

0.00~1.00

± 0.10

1.00~3.00

Truth value ± 10%

3.00~4.00

± 0.30

 

2. O2

Measuring range

Error expected

0.0~5.0

± 0.5

>5.0~30.0

Measuring value ± 3%


3. CO

                                                       Measuring range

Intrinsic error

Absolute   error

Relative   error

0~20

± 2

——

>20~100

± 4

——

>100~500

——

Truth value ± 4%

>500~1000

——

Truth value ± 5%

>1000~2000

——

Truth value ± 6%


4. H2S

Measuring range

Intrinsic error

0~49

± 3

50~100

Truth value ± 10%

>100~500

Truth value ± 15%


5. Response time: T<30s

6. Indicating method: LCD screen displays real-time data and system status.

7. Working environment: temperature -20~50

8. Humidity<95%RH, no condensation

9. Voltage: DC3.7V

10. Recharge time: 6h~8h

11. Stand-by time: >8 hours

12. Sensor lifetime: 2 years

13. Levels of protection: IP65

14. Dimension: 68mm×33mm×124mm

15. Weight: 400g


Contact Supplier

Mr. Haicheng Lu Foreign trade salesm Chat Now
Telephone
86-516-83890183
Mobile
86-18012019981
Fax
86-516-83890183
Skype
live:3cde26307dccf7be
Address
Quanshan Xuzhou,Jiangsu

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Flow Measuring Instruments > Gas Meters
Categories
Hi~