5l Mini Lab glass vacuum distillation equipment Liquid Evaporator
USD $1,359 - $1,431 /Unit
Min.Order:1 Unit
Gezhiling Mechanical & Electrical Co., Ltd.
RE-5000E liquid evaporator mainly used for continuous distillation of a large amount of volatile solvent under negative pressure. Especially for the concentration of extract liquor and distillation of receive liquid when chromatograph, it can isolate and purify reaction product. In reduced pressure condition, when solvent distillation, distillation flask in continuous rotation, the distillation flask is a pyriform or round-bottom flask who is connected to vacuum pump by a snakelike condenser pipe, the other open mouth of condenser pipe is connected to receiving flask to receive evaporated organic solvent. There is a three-way valve between condenser pipe and vacuum pump, when system connect to air, take down distillation flask and receiving flask to transfer solvent. Please reduce pressure first before rotate distillation flask; and please power off first before connect to air, to prevent the rotating distillation flask from falling off. Thermostatic water bath is the heat source for distillation. RE-5000E rotary evaporator mainly used in medicine, chemical engineering, biopharmacy industries for the concentration, crystallization, drying, separation and solvent recovery, especially suitable for concentrate and purify high temperature easily decomposed material.
Technical Parameter of Lab Concentration Liquid Evaporator
Basic Parameter | Model | RE-5000E |
Glass Material | GG-17 | |
Support Material | Aluminium Alloy | |
Inner Container Material | Aluminium Alloy+Teflon recombination pot, whole sealing heating 280*170mm 10L | |
Rotary Bottle Volume | 5L 50# flange port | |
Receiving Flask Volume | 3L 35# ball milling port | |
Rotary Power | 40W | |
Rotary Speed | 0-180rpm | |
Heating Power | 1.5KW | |
Bath Kettle Temp. Control Range | 0-99℃ | |
Temp. Control Accuracy | ±1℃ | |
Lifting Power | 20W | |
Lifting Stroke | 120mm | |
Voltage/Frequency (V/Hz) | 220V/50Hz | |
Overall Dimension (mm*mm*mm) | 700*410*880 | |
Package Dimension (mm*mm*mm) | 640*540*690 wooden case | |
Package Weight (KG) | 42.5 | |
Functional Configuration | Rotary Speed Display Mode | Liquid Crystal Display |
Temperature Display Mode | PT100 Sensor Digital Display | |
Temperature Control Mode | Intelligent Temperature Control | |
Sealing Mode | Bothway sealing by Teflon + Fluorine Rubber | |
Lifting Mode | Automatic lifting of main engine | |
Condenser | Vertical type condenser 100*590mm | |
Continuous Charging | 19# charging valve | |
Our company's laboratory glass and laboratory instruments are independent research and development, available for custom-made according to client requirements. |
Packing List of Lab Concentration Liquid Evaporator
Machine Part | Glass Part | ||
Head with the motor | 1 set | Rotary Bottle | 1 pc |
Host | 1 unit | Recycling bottle | 1 pc |
Control box | 1 pc | Condenser | 1 pc |
Bath pot | 1 unit | 19# feeding valve | 1 pc |
Recycling bottle clamp | 1 pc | Adapter | 1 pc |
PTFE Tube | 1 pc | Glass Shaft | 1 pc |
Heating wire | 1 pc | ||
Fasten Screw | 1 pc | ||
PTFE Flask remover | 1 pc | ||
Nut with pad | 2 sets | ||
Spare Parts | |||
Operation Manual | 1 pc | 10A fuse | 2 pcs |
Warranty Card | 1 pc | Sealing gasket | 1 pc |
Quality Certificate | 1 pc | Packing List | 1 pc |
1. Rotary vacuum evaporator matching use with circulating water vacuum pump to offer a vacuum environment for reduced pressure distillation, they are widely used for vacuum filtration, vacuum evaporation, vacuum degassing, etc..
2. Rotary vacuum evaporator matching use with GDSZ series high and low temperature circulating pump to quickly cooling or warming, the circulating pump is an efficient equipment for quick temperature adjustment.
3. Rotary vacuum evaporator matching use with DLSB series low temperature cooling liquid circulating pump to conduct chemical reaction and medicine storage which requires low temperature environment.
Q: What’s the difference between vertical and inclined condenser?
A: They have no difference essentially. Vertical condenser is gradually popular because of its small space usage and convenience for transportation and use. Most high-capacity instruments use vertical condenser.
Q: What factor decides the working efficiency of Thermal Rotary Evaporator?
A: For same type equipment, mainly includes: steam temperature, vacuum degree and cooling water temperature. Restricted by some material’s thermolability, the steam temperature may have certain limitation when working, so high vacuum degree and low cooling water temperature are two main factors for efficiency improving.
Q: How to select all kinds of Thermal Rotary Evaporator?
A: As for structure, our R series products all have excellent corrosion resistance ability and leakproofness ability. According to the solvent volume, 2L, 3L, 5L’s machine is fit for lab and sample test; 5L, 10L, 20L’s machine is fit for medium experiment; 20L, 50L’s machine is fit for medium experiment and production, especially suitable for the extraction of metal ionavoiding polluted material.