HCL-B1 Electrochemical Hydrogen Chloride Sensor (HCL Sensor)

HCL-B1 Electrochemical Hydrogen Chloride Sensor (HCL Sensor)

USD $30 - $120 /Piece

Min.Order:1 Piece

Supply Ability:
3000 Piece / Pieces per Month
Port:
HK
Payment Terms:
T/T PayPal
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
HCL-B1
Usage:
Gas Sensor
Theory:
Other, Electrochemical Gas Sensor
Output:
Analog Sensor

Shenzhen Isweek Ltd.

Business Type: Distributor/Wholesaler
Main Products: Gas Sensor ,UV Sensor ,Humidity Sensor ,Pressure Sensor ,Ultrasonic Sensor ,Wind Speed sensor ,Liquid Level Sensor

Product Details

HCL-B1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.

Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.

HCL-B1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE
Sensitivity
nA/ppm in 25ppm HCl
150 to 250
Response time
t90 (s) from zero to 25ppm HCl
<200
Zero current
ppm equivalent in zero air
0 to 3
Resolution
RMS noise (ppm equivalent)
<0.1
Range
ppm HCl limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm HCl
0 to 6
Overgas limit
maximum ppm for stable response to gas pulse
200



HCL-B1 Hydrogen Chloride Sensor HCL Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
nd



HCL-B1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL
Sensitivity @ 0°C
% (output @ 0°C/output @ 20°C) @ 25ppm HCl
80 to 95
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 25ppm HCl
100 to 108
Zero @ -20°C
ppm equivalent change from 20°C
<+0 to -1.0
Zero @ 50°C
ppm equivalent change from 20°C
<+0.5 to +2.5



HCL-B1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY
H2S   sensitivity
% measured gas @ ppm H2S
<280
NO2   sensitivity
% measured gas @ ppm NO2
<-150
Cl2     sensitivity
% measured gas @ ppm Cl2
<-100
NO     sensitivity
% measured gas @ ppm NO
<2
SO2   sensitivity
% measured gas @ ppm SO2 (transient peak)
<1
CO     sensitivity
% measured gas @ ppm CO
<0.1
H2     sensitivity
% measured gas @ ppm H2
<0.1
C2H4 sensitivity
% measured gas @ ppm C2H4
<0.1
NH3   sensitivity
% measured gas @ ppm NH3
<0.1
CO2   sensitivity
% measured gas @ 5% CO2
<0.1



HCL-B1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to +50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 33
Bias voltage
mV
not required
Weight
g
<13


Matched Transmitter board for HCL-B1 HCL Sensor

4-20mA Analogue Transmitter Board
  • Factory calibration, custom-set for immediate use
  • Wide operating voltage range
  • Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.


4-20mA Digital Transmitter Board
   • Factory calibration, custom-set for immediate use
   • Digital zero, sensitivity and temperature compensation
   • Digital and 4-20mA output
   • Biased or unbiased operation
   • Calibration and range change


Contact Supplier

Ms. Ms Rita yu Sales Chat Now
Telephone
86-755-83289036
Mobile
86-15216024218
Fax
86-755-83289052
Skype
Isweek_Rita
Address
16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~