HCL-B1 Electrochemical Hydrogen Chloride Sensor (HCL Sensor)
USD $30 - $120 /Piece
Min.Order:1 Piece
HCL-B1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.
Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.
HCL-B1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 25ppm HCl | 150 to 250 |
Response time | t90 (s) from zero to 25ppm HCl | <200 |
Zero current | ppm equivalent in zero air | 0 to 3 |
Resolution | RMS noise (ppm equivalent) | <0.1 |
Range | ppm HCl limit of performance warranty | 100 |
Linearity | ppm error at full scale, linear at zero, 40ppm HCl | 0 to 6 |
Overgas limit | maximum ppm for stable response to gas pulse | 200 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | nd |
Sensitivity drift | % change/year in lab air, monthly test | nd |
Operating life | months until 80% original signal (12 month warranted) | nd |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL | ||
Sensitivity @ 0°C | % (output @ 0°C/output @ 20°C) @ 25ppm HCl | 80 to 95 |
Sensitivity @ 50°C | % (output @ 50°C/output @ 20°C) @ 25ppm HCl | 100 to 108 |
Zero @ -20°C | ppm equivalent change from 20°C | <+0 to -1.0 |
Zero @ 50°C | ppm equivalent change from 20°C | <+0.5 to +2.5 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY | ||
H2S sensitivity | % measured gas @ ppm H2S | <280 |
NO2 sensitivity | % measured gas @ ppm NO2 | <-150 |
Cl2 sensitivity | % measured gas @ ppm Cl2 | <-100 |
NO sensitivity | % measured gas @ ppm NO | <2 |
SO2 sensitivity | % measured gas @ ppm SO2 (transient peak) | <1 |
CO sensitivity | % measured gas @ ppm CO | <0.1 |
H2 sensitivity | % measured gas @ ppm H2 | <0.1 |
C2H4 sensitivity | % measured gas @ ppm C2H4 | <0.1 |
NH3 sensitivity | % measured gas @ ppm NH3 | <0.1 |
CO2 sensitivity | % measured gas @ 5% CO2 | <0.1 |
HCL-B1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS | ||
Temperature range | °C | -30 to +50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months @ 3 to 20°C (stored in original container) | 6 |
Load resistor | Ω (recommended) | 10 to 33 |
Bias voltage | mV | not required |
Weight | g | <13 |
Matched Transmitter board for HCL-B1 HCL Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change