DSEL401 MKII Intelligent Lighting Tower Control Module
USD $188 - $199 /Pallet
Min.Order:1 Pallet
Zhongnan electronic technology co. LTD
DSEL401 MKII
Intelligent Lighting Tower Control Module
The DSEL401 MKII is an intelligent control module designed specifically for mobile lighting tower applications. The control module provides class leading flexible features that are fully configurable to suit multiple complex lighting sequences.
OVERALL SIZE
140 mm x 113 mm x 43 mm (5.5” x 4.4” x 1.7”)
PANEL CUTOUT SIZE
118 mm x 92 mm (4.6” x 3.6”)
MAXIMUM PANEL THICKNESS
8.0mm (0.3”)
WEIGHT
0.28kg
PRODUCT VARIANTS
L401-01 - L401 MKII Intelligent Lighting Tower Control Module (Rtc)
24 Volt 20 Amp Intelligent Battery Charger
The DSE9476 is an intelligent 24-volt, 20 amp switch-mode battery charger that can be programmed for different charging curves. This helps to maximise battery life.
OVERALL SIZE
183 mm x 233 mm x 76 mm (7.2” x 9.2” x 3.0”)
WEIGHT
1.8kg
PRODUCT VARIANTS
9476-01 - 24 V 20 A Intelligent Battery Charger
Automatic Transfer Switch Controller
The DSE327 is an Automatic Transfer Switch Control Module designed to monitor the voltage of an incoming AC supply from two different sources. This could be from both generator or mains (utility), or a combination of both. The module monitors S1 (Source 1) and in the event of a failure issues a start command to S2 (Source 2). The DSE327 can be ordered in 110 V and 230 V variants.
READ MORE
OVERALL SIZE
72 mm x 90.5 mm x 65 mm (2.8” x 3.6” x 2.6”)
WEIGHT
0.3 kg
PRODUCT VARIANTS
0327-01 - 327 Auto Transfer Switch Control Module (230 Volt)
0327-02 - 327 Auto Transfer Switch Control Module (110 Volt)
Activation of an input configured to mains load inhibit or generator load inhibit inputs cause the corresponding breaker to be opened immediately. No other change in function will occur.
When the input is deactivated the load transfer scheme is followed as below.
If an input configured to Load Shed is activated, outputs set to Open Mains and Open Gen will energise, and inputs configured to Close Mains and Close Gen will de-energise. Open Mains Pulse and Open Gen Pulse outputs will only energise if the corresponding supply was on load before application of the Load Shed input. When the Load Shed input is deactivated, the load will be transferred back to the supply that was disconnected before application of the input.
When the load is about to be transferred, the check sync function is activated. When the mains and generator are within the phase and frequency window the module transfers the load as shown below.
The module waits indefinitely for synchronisation unless Return to programmed transition is active in which case after 2 minutes it performs a non-sync transfer as described in the previous section.