Product Details

SMT3151 DP/HP Differential Pressure/High Static Pressure Differential Pressure Transmitter

Brand Name SMT3151 DP/HP
Place of Origin China
Model Number SMT3151 DP/HP Differential Pressure/High Static Pressure Differential Pressure Transmitter

Product Features

SMT3151DP/HP Differential Pressure/High Static Pressure Differential Pressure Transmitter



Description

Differential pressure/high static pressure differential pressure transmitter is a pressure signal measured at the reference end of the low-pressure side and has two ports connected to the process pipe.

The working principle of the metal capacitive differential pressure/high static pressure differential pressure transmitter is that when the pressure acts indirectly on the surface of the metal measuring diaphragm (elastic measuring element) of different thickness through the isolating diaphragm and the guiding medium, the diaphragm is slightly generated. The maximum deformation does not exceed 0.1mm. The high-precision circuit for measuring the deformation of the diaphragm transforms this tiny deformation into a voltage signal proportional to the pressure, through the linearization and temperature compensation, and then uses a dedicated chip to convert this voltage signal to an industry standard 4-20mA current signal or a 1-5V voltage signal.

The high sensitivity of the metal capacitive pressure sensor and the high precision integrated circuit used in the measurement diaphragm detection circuit contain linear and temperature compensation circuit, so the whole transmitter can achieve high precision and high stability.

The metal capacitive pressure sensor has extremely high overload resistance and excellent performance in micro-pressure measurement. It is also a must choice product in various complex industrial environments.

Technical Performance

Use object: liquid, gas or steam

Measuring range: see the selection specification table

Output signal: 4-20mA dc. Output, superimposed HART protocol digital signal (two-wire system)

Power source: external power supply 24V dc. Power supply range 12V ~ 45V

 

Load characteristics:

1


Installation in dangerous places:

Flameproof  ExdIIBT5Gb;(explosion-proof certificate no. :CE16.1163)

Intrinsically safe ExiaIICT4/T5/T6Ga;(explosion-proof certificate no. : CE15.2354X) ;

Migration features:

At the minimum range (the range compression ratio is 40:1), the maximum positive transfer zero point is 39/40 times the upper limit of the range, the maximum negative transfer zero point can be the lower limit of the range, the absolute pressure transmitter has no negative transfer.(regardless of the output form, the upper and lower limits of the range shall not exceed the limit of the range after positive and negative migration)

Temperature range:       

Electronic circuit board work in: - 40 ~ 85 ℃;

Sensitive components work in: - 40 ~ 85 ℃;

Storage temperature: - 40 ~ 85 ℃;

With digital display: - 25 ~ 75 ℃ (run);

 - 40 ~ 85 ℃ (no damage);

Relative humidity: 0 ~ 95%

Overpressure limit: DP type, plus 0 (absolute pressure) ~ 13MPa (or 1.5 times the upper limit of the range) pressure transmitter is not damaged. High static pressure type with a static pressure or one-way pressure of up to 31 MPa.

Volume change: less than 0.16cm3

Damping:The time constant is adjustable from 0.2 to 32.0s.

Startup time: 3s, no preheating required.

Technical Index

 (non-removable, 316 stainless steel isolation diaphragm and other standard test conditions.)

Accuracy: ± 0.1%, ±0.2%

Stability: ±0.25%/6 months of maximum range

Temperature: including zero and range for maximum temperature error of ±0.2%/20℃

Static pressure effect:

(DP type in linear output) zero point error: after adding static pressure 140kgf/cm2, the zero error of range 4, 5 is + 0.25% of the maximum range, and the zero error of range 3, 6, 7, 8 is + 0.5% of the maximum range.This is the system error. Before installation, the transmitter zero point can be adjusted according to the actual static pressure to eliminate this error.

(HP type in linear output)Zero point error: when static pressure is added to 31.2MPa, the zero error is less than ±2.0% of the maximum range. This is the system error. Before installation, the transmitter zero point can be adjusted according to the actual static pressure to eliminate this error.

Power supply impact: less than 0.005% / V of the output range.

Vibration effect: in any axial direction, the frequency is 200Hz, and the error is ±0.05% / g of the maximum range.

Load effect: as long as the input transmitter voltage is higher than 12V, there is no load effect in the load working area.

Influence of installation location: zero error of no more than 0.25kPa can be generated at the maximum, which can be eliminated by correction without any impact on the range; The measuring body has no influence on relative flange rotation.

Application and type selection:

Common differential pressure transmitter is the most commonly used test instrument in industrial process control. It is widely used in various automatic control systems, such as aerospace, military, petrochemical, chemical, oil Wells, electric power, ships, building materials, pipelines and many other industries.Generally used in liquid, gas or steam differential pressure, flow measurement, medium temperature is not too high, corrosion is not strong, viscosity is not high, not easy to crystallize and other environments.If the working static pressure exceeds 13MPa, a high static differential pressure transformer should be selected.

Attention to type selection:

Before selecting the type, the user shall make clear the temperature, corrosion, measuring range, use, whether the medium under test is explosion-proof, whether the oil shall be forbidden, whether the medium is easy to crystallize or thicken, whether the diaphragm flange connection is needed, etc.

SM3151DP/HP Differential Pressure/High Static Pressure Differential Pressure Transmitter Selection Specifications Table

Model

Transmitter type

SM3151DP

SM3151HP

Pressure transmitter

Absolute pressure transmitter

Code

Scale range

2

3

4

5

6

7

8

9

0

0-0.103.5kPa(0-10350mmH2O)

0-0.88.0kPa(0-80800mmH2O)

0-4.040kPa(0-4004000mmH2O)

0-20200kPa(0-200020000mmH2O)

0-70700kPa(0-0.77kgf/cm2)

0-2102100kPa(0-2.121kgf/cm2)

0-7007000kPa(0-7.070kgf/cm2)

0-2.121MPa(0-21210kgf/cm2)

0-4.141MPa(0-414100kgf/cm2)

Code

Output form

E

Linear output 4-20mAdc

SF

Linear/square root output 4-20mAdc   +HART signal,Full function buttons on site

F

MODBUS-485 signal

Code

Structural materials

Flange connector

Exhaust/Drain valve

Isolation diaphragm

Filling liquid

22

316 Stainless   steel

316 Stainless   steel

316 Stainless   steel

Silicone oil

23

316 Stainless   steel

316 Stainless   steel

Hastelloy C

Silicone oil

24

316 Stainless   steel

316 Stainless   steel

Monel

Silicone oil

Silicone oil

25

316 Stainless   steel

316 Stainless   steel

Tantalum

33

Hastelloy C

Hastelloy   C

Hastelloy C

Silicone oil

35

Hastelloy C

Hastelloy   C

Tantalum

Silicone oil

44

Monel

Monel

Monel

Silicone oil

Code

Shell material

Conduit inlet dimensions

A

Low copper aluminum alloy   polyurethane coating

M20×1.5

B

Low copper aluminum alloy   polyurethane coating

1/2-14 NPT

C

Stainless steel

M20×1.5

D

Stainless steel

1/2-14 NPT

Code

Pressure connection

L1

1/4NPT-18 Internal threadexcluding waist joint standard

L2

1/2NPT-14 Internal thread

L3

M20×1.5 External thread

Code

Optional parts

M4

LCD multi - power digital display   head

B1

Pipe bending bracket

B2

Plate bending bracket

B3

Pipe mounting bracket

C02

M20×1.5 nut and Φ 14 pressure short tube


C12

1/2NPT-14 external thread and Φ14   pressure short tube


C22

1/4NPT-18 external thread and Φ14   pressure short tube


C32

1/4NPT-18 to M20×1.5 external   thread


C42

1/2NPT-14 to M20×1.5 external   thread


C43

1/2NPT-14 to 1/4NPT-18 internal   thread


C44

1/2NPT-14 to 1/2NPT-14 external   thread


C45

1/2NPT-14 to G1/2 external thread


D1

The side discharge valve is on the   upper part

D2

The side discharge valve is on the   upper part

X1

Oil ban

Da

Flameproof   ExdIIBT5Gb;(explosion-proof certificate no. : CE16.1163)

Fa

Intrinsically safe ExiaIICT4/T5/T6Ga;(explosion-proof   certificate no. : CE15.2354X)


You May Like

Find Similar Products By Category

You May Like

View More
Chat Now Contact Now