Competitive price low temperature plasma heat sterilizer tunnel
USD $7890 - $15666 /Piece
Min.Order:1 Piece
MEDBES International Trading CO., LTD.
Model M-D
Type Vertical (full automatic)
Heating method Electric
Install environment 5-45℃
Sterilizing temperature 50℃
Working pressure 50pa
Sterilize agent Hydrogen peroxide solution(60%H202)
Sterilizing time 45-50min
Vacuum speed Absorb to 50pa in five minutes
Temperature display LCD touch screen
Highest anti-pressure value 10pa
Operation height ≤160cm, more humanization operation height so that convenient for women.
Parameters:
Chamber material: The chamber structure is rectangular, can improve the space utilization; It use 304 anti-corrosion type stainless steel or aluminum 5052; thickness ≥ 8 mm, with excellent thermal conductivity, to ensure that hydrogen peroxide to maintain 100% gaseous.
Carton material: ABS
Electrode material: Aluminum alloy material 5052, sheet metal forming, thickness ≥ 3 mm
Sealing door material: Use 5052 aluminum alloy material, thickness ≥ 15 mm
Loading method: The two layers of aluminum alloy punching plate loaded sterile items, big loading capacity, high space usage.
Door open mode: using mandrel drive electric lift door.
Door protection function: With door barrier switch function, when touch the barrier switch, the door automatically stop, to prevent injure the operator and damage the items.
Chamber temperature heating power: 2.75kw, pre-heating time ≤ 30 min. It can meet the chamber heating power and heating up more faster.
Main insulation: ≥ 20 mm suction cotton, with a low thermal conductivity, fire performance, anti-aging ability, non-toxic environmental protection and the appearance of high-grade soft texture and so on.
Full automatic control system: LCD touch screen display, PLC intelligent control system. One button to control from start to end and finish automatically with showing temperature, pressure, sterilization time. The system can maintenance and upgrade.
Printer: Adapting to micro printer to printing each data of every minute during the sterilization process, also can storage permanently. It can print the following data: process name, sterilize date, sterilize time, sterilization start&end time, the variation data of pressure and temperature during the sterilization process, stage time and end status and other information, also provide print samples.
PLC: Use imported Siemens smart series PLC control system.
Display: 7-inch color touch screen, communication rate ≥ 19.2 Kbps.
Display status: Temperature, pressure, time, cycle mode, process stage and alarm information, and provide the actual interface photo.
U disk storage function: Disk capacity ≥ 8G, it can store records more than one million sterilization data, storage information, including program serial number, sterilization date, sterilization pot, sterilization start&end time and sterilization process pressure, Temperature, stage time and end status and other information, and provide computer graphics samples.
Biological Indicator Cultivator: Microcomputer-controlled biological indicator special temperature incubator for the monitoring of biological effects of biological indicators of the constant temperature culture process, the full range of ≤± 3℃ temperature control accuracy; temperature can be set
Pressure sensor: Inner with pressure sensor which imported from Japan to check chamber pressure automatically, to ensure that the chamber pressure is accurate and effective.
Temperature sensor: Inner with temperature sensor to check chamber temperature automatically,to ensure that chamber temperature within precise range of 50℃±3℃.
Program System: There are two procedures to strengthen the cycle and fast cycle. Strengthen the cycle ≤ 50 minutes, fast cycle ≤ 30 minutes.
Vacuum system: Adapting high strength vacuum pump, the vacuum speed is fast and the service life is long.
Vacuum pump: Use high degree of vacuum and resistance to H2O2 corrosion of the rotary vane vacuum pump.
Vacuum pump phase sequence protection: With a vacuum pump phase sequence protection device to prevent the power supply phase sequence changes, leading to reverse the vacuum pump to the sterilization chamber. Single-phase vacuum pump, easier to install, no phase sequence protection.
Absorb control valve: adopts high vacuum baffle solenoid valve to control the pumping pipe.
Oil mist filter: The product has an exhaust oil mist filtration system, which can recover oil mist, avoid oil mist into the air, and pump the pump oil back to the pump to reduce fuel consumption.
Air filter: The filter accuracy is less than or equal to 0.2μm.
Plasma power: using transistor control power, power ≤ 500W, strong analytical ability.
Sterilization effect: Domestic first invent that can make cavity instrument disinfect thoroughly from 2 meters to 4 meters. Offer provincial sterilization effect certificate report.
Heating system: Adapting to anti-explosion and fire resistance heating system, temperature is more precise, more convenient and fast.
Electromagnetic compatibility testing: Provide the provincial testing agencies electromagnetic compatibility test report.
Various protective function: It has set up over temperature protection function and show on LCD screen if fault, to make the after sales-service dealing with fault more efficiently.
Caster: Yes.
Alarming system: Equipped with high&low temperature alarming system.
Category: Class B.
No. Model Volume Chamber size(L*W*H) Carton size(L*W*H) Power
(kw) Gross weight(kg) Power supply
1 M-D100 100L 700 x 430 x 360mm 1080*800*1710mm 3.95 340 AC220V/50HZ
2 M-D130 130L 750 x 450 x 400mm 1080*800*1710mm 4.35 360 AC220V/50HZ
3 M-D220 190L 820 x 510 x 460mm 1080*800*1710mm 5.15 450 AC380V/50HZ