11/4“ Electric Actuator For Valve Control with indicator no manual
USD $5 - $100 /Piece
Min.Order:1 Piece
3 Way Horizontal stainless steel L Type Electric Actuator Ball Valve
1/2 inch 3 Way Nickel plated Brass T type Electric Actuator Ball Valve
AC220V DN10 3/8inch stainless steel 2way motorized ball valve with indicator no manual
DN20 3/4'' Stainless Steel 2pieces mini Motor Operated Ball Valve without indicator and manual
One.Product data:
11/4" Electric Actuator For Valve Control with indicator no manual
Technical Parameters:
CR2-01, CR2-02 , CR3-03, CR4-01, CR5-01, CR5-02, CR7-03, CR7-04 (Optional) DC12V, DC24VSuitable valve size NPT/BSP 11/4", NPT/BSP 11/2", NPT/BSP 2" (Optional) Maximum working pressure 1.0MPa Circulation medium Fluid, Air Rated voltage DC12V, DC24, AC/DC9-35V, AC110-230V(Optional) Wiring control methods Working current ≤ 800MA Open/close time ≤ 15 Sec Life time 50000 times Valve Body material Stainless Steel 304 Actuator material Engineering Plastics Sealing material EPDM & PTFE Actuator rotation 90° Max. torque force 10 Nm Cable Length 0.5m,1.5m (Optional) Environment temperature -15℃~50℃ Liquid temperature 2℃~90℃ Manual override NO Indicator Yes Protection class IP67
Specifications:Model Wiring control Working voltage Max. torque A100 CR2 01 10Nm A100 CR2 02 AC/DC9-35V 10Nm A100 CR3 03 DC12V, DC24V 10Nm A100 CR4 01 AC110-230V 10Nm A100 CR5 01 DC12V, DC24V 10Nm A100 CR5 02 AC/DC12-24V 10N.M A100 CR7 03 DC12V, DC24V 10N.M A100 CR7 04 AC110-230V 10N.M
Wiring diagram:CR2 01 Wiring Diagram ( 2 wires control )·RD connect with positive, the BK connect with negative, the valve closed, the actuator automatically power off after in place , the valve remains fully closed position ﹡Exceeding the working voltage is forbidden CR2 02 Wiring Diagram ( 2 wires control – Spring return in case of the power failure) ·When SW is closed , the valve open. the actuator automatically power off after in place ·When SW is open, the valve closed, the actuator automatically power off after in place ﹡Exceeding the working voltage is forbidden ·RD& GR connect with positive, the BK connect with negative。 ·SW CLOSED, the valve OPEN, the actuator automatically power off after in place ·SW OPEN, the valve CLOSED, the actuator automatically power off after in place. ﹡Suitable Working Voltage: AC/DC9-35V/AC110-230V ﹡Exceeding the working voltage is forbidden CR5 01 Wiring diagram ( with feedback signal) 1RD connect with positive, the BK connect with negative,the valve closed, the actuator automatically power off after in place . 2 BK connect with positive, the RD connect with negative,the valve open, the actuator automatically power off after in place . 3.BL & WT are connect when the valve open fully, YW & WT are connect when the valve closed fully Suitable Working Voltage::DC12V,DC24V Exceeding the working voltage is forbidden CR502 Wiring Diagram ( 5 wires control – Spring return) ·When SW is closed , the valve open. the actuator automatically power off after in place ·When SW is open, the valve closed, the actuator automatically power off after in place BL & WT are connect when the valve open fully, YW & WT are connect when the valve cl osed fully ﹡Suitable Working Voltage: AC/DC9-24V,AC/DC110V-230V, ﹡Exceeding the working voltage is forbidden CR7 03 Wiring Diagram ( 7 wires control with feedback signal ) ·RD& GR connect with positive, the BK connect with negative。 ·SW CLOSED, the valve OPEN, the actuator automatically power off after in place ·SW OPEN, the valve CLOSED, the actuator automatically power off after in place. ·BL & GY connect with the valve’s fully open signal wiring ·YW & WT connect with the valve’s fully closed signal wiring. ﹡Suitable Working Voltage: DC12V,DC24V ﹡Exceeding the working voltage is forbidden CR7 04 Wiring Diagram ( 7 wires control with feedback signal ) ·RD & BK are connected to the power, WT & YW are connected to the controlled wiring. ·When the SW is closed , the valve open ·When the SW is open , the valve closed ·BL & GY connect with the valve’s fully open signal wiring ·YW & WT connect with the valve’s fully closed signal wiring. Suitable Working Voltage::AC/DC110V-230V Exceeding the working voltage is forbidden
·BK connect with positive, the RD connect with negative, the valve open, the actuator automatically power off after in place, the valve remains fully open position .
﹡Suitable Working Voltage: DC5V/DC12V/DC24V
﹡Suitable Working Voltage: AC/DC9-35V
Two related product:
Three.Company information:
Three.Company profile
Tianjin Nbestvalve Co., Ltd. was established in 2002, headquartered in No.21,No.1 Building, Ronghui Business Zone, Zhongguancun technology Park, Binhai New District, Tianjin, China. With the rapid development of the most dynamic Chinese Bohai Economic Rim, Our company, production, sales and manufacturing test capabilities, with independent import and export rights, is a science, industry and trade as one of the group enterprise.
Four.Aplication Area
a. Domestic sewage treatment.
b. industrial wastewater treatment.
c. industrial irrigation treatment.
Five.Packing and Freight
Six.FAQ
Q: Are you trading company or manufacture?
A: We are factory located in Tianjin, China.
Q: What's your product range?
A: We specialize in product butterfly valves,solenoid valve, gate valves, check valves, Y type strainer, water controlling valves,motorized valves,pneumatic valves,hydraulic valves and other pipe accessories.
Q: What's execution standard?
A: ISO/ANSI/DIN/JIS/EN/GOST standard.
Q: What's your strong product?
A: Concentric butterfly valves, grooved butterfly valves, dual plate check valves.
Q: Do you provide sample? Is it free or extra?
A: Yes, we could offer the sample for free charge but do not pay the cost of the freight.
Q: How long is your delivery time?
A: Generally it is 7 days if the good are in stock, or it is 20 days if the goods are not in stock, it is according to the quantity.
Q: What is your terms of payments?
A: Payment ≤10000 USD, 100% in advance. Payment ≥10000USD, 30% T/T or other ways in advance, balance before shipment.
Seven.Contact us