Ethylene Oxide Residue Tester GC-7960
USD $99 - $10000 /Set
Min.Order:1 Set
Systester Instruments Co., Ltd
Ethylene Oxide Residue Tester GC-7960
Application
GC-7960 Ethylene Oxide Residue Tester applies to test of solvent residue on various printing films, laminated films, extrusion films, various drug-use films and sheets as well as various kinds of sterilization apparatus and instruments. It is one highly cost-effective tester and SYSTESTER launched GC-7960 specially for food & pharmaceutical industries, quality inspection departments as well as research and development institutions.
Characteristics
1. Professionally ethylene oxide residue test.
2. Microcomputer controls, LCD displays.
3. PVC keyboard, easy to operate.
4. Dual CPUs design, excellent electromagnetic interference protection.
5. Dual FID detectors, dual gas circuits system, self-diagnosis function.
6. Ignite automatically.
7. Constant and programming temperature control function.
8. Temperature control accuracy over 0.1°C.
9. 8 grades temperature programming function.(Personal customization available)
10. Temperature rising fast, highly efficient capillary column, zero-dead volume.
11. Bigger oven design.
12. Variable frequency cooling system, easy to do a nearest room temperature test.
13. Record parameters automatically even power’s down.
14. Over temperature protection function.
15. Carrier gas flow monitoring to protect TCD detector and oven column.
16. Self-diagnosis function, trouble is easy to resolve.
17. Powerful chromatographic work station.
Technical Indexes
1. Temperature Control:
Oven: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Injector: room temperature +8~ 420°C, accuracy ±0.1°C (at 200°C)
Detector: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
2. Oven
Temperature Control: room temperature +8~420°C, accuracy ±0.1°C (at 200°C)
Dimension: 280mm X 280mm X 250mm
Programmed Temperature: 8 grades. (Personal customization available)
Programmed Temperature rising rate: 1°C ~50°C
Dwell time at One Grade: 0~300min
3. FID Detector
Detection Limit: ≤8×10-12 g/s (Hexadecane/Isooctane)
Baseline Noise: ≤0.02
Baseline Drift: ≤0.15
Linearity: 106
Signal Stabilization Time:<20min
Ignition: Auto.
Standards
YBB20162012、YBB20172012、YBB20182012、YBB20252012、YBB20262012、YBB20272012
Configuration
Standard Configuration: Gas chromatograph, FID detector, professional column, GC workstation.
Optional: Headspace injection device, air generator, hydrogen generator, nitrogen generator.
Note: Specifications are subject to change without prior notice.