CO-BX Low Hydrogen Cross Sensitivity Carbon Monoxide Sensor CO Sensor
USD $40 - $80 /Piece
Min.Order:1 Piece
CO-BX Carbon Monoxide Sensor CO Sensor Description
Alphasense Carbon Monoxide gas sensors operate using proven fuel cell technology.
CO-BX Carbon Monoxide Sensor size:
32mm diameter package, the best choice for fixed site applications
The Alphasense family of CO sensors have proven themselves in the field with long term stability and reliable operation, well beyond the two-year warranty, using our patented electrode technology. The ‘X’ sensors have low hydrogen sensitivity, as drop-in replacements for the standard ‘F’ sensors.
CO-BX Carbon Monoxide Sensor CO Sensor PERFORMANCE | ||
Sensitivity | nA/ppm in 400ppm CO | 70 to 130 |
Response time | t90 (s) from zero to 400ppm CO | <25 |
Zero current | ppm equivalent in zero air | <± 3 |
Resolution | RMS noise (ppm equivalent) | <0.5 |
Range | ppm limit of performance warranty | 2,000 |
Linearity | ppm CO error at full scale, linear at zero, 1000ppm CO | <± 20 |
Overgas limit | maximum ppm for stable response to gas pulse | 5,000 |
CO-BX Carbon Monoxide Sensor CO Sensor LIFETIME | ||
Zero drift | ppm equivalent change/year in lab air | <0.2 |
Sensitivity drift | % change/year in lab air, monthly test | <3 |
Operating life | months until 80% original signal (24 month warranted) | > 24 |
CO-BX Carbon Monoxide Sensor CO Sensor ENVIRONMENTAL | ||
Sensitivity @ -20℃ | % (output @ -20℃/output @ 20℃) @ 400ppm CO | 40 to 60 |
Sensitivity @ 0℃ | % (output @ 0℃/output @ 20℃) @ 400ppm CO | 65 to 85 |
Sensitivity @ 50℃ | % (output @ 50℃/output @ 20℃) @ 400ppm CO | 110 to 130 |
Zero @ -20℃ | ppm equivalent change from20℃ | <0 to 4 |
Zero @ 0℃ | ppm equivalent change from 20℃ | <0 to 3 |
Zero @ 50℃ | ppm equivalent change from 20℃ | <0 to -6 |
CO-BX Carbon Monoxide Sensor CO Sensor CROSS SENSITIVITY | ||
Filter capacity | ppm·hrs H2S | 160,000 |
Filter capacity | ppm·hrs NO2 | 120,000 |
Filter capacity | ppm·hrs NO | 120,000 |
Filter capacity | ppm·hrs SO2 | 160,000 |
H2S sensitivity | % measured gas @ 20ppm H2S | <0.1 |
NO2 sensitivity | % measured gas @ 10ppm NO2 | <1 |
Cl2 sensitivity | % measured gas @ 10ppm Cl2 | <0.1 |
NO sensitivity | % measured gas @ 50ppm NO | <25 |
SO2 sensitivity | % measured gas @ 20ppm SO2 | <0.1 |
H2 sensitivity | % measured gas @ 400ppm H2 at 20℃ | <5 |
C2H4 sensitivity | % measured gas @ 400ppm C2H4 | <10 |
NH3 sensitivity | % measured gas @ 20ppm NH3 | <0.1 |
CO-BX Carbon Monoxide Sensor CO Sensor KEY SPECIFICATIONS | ||
Temperature range | ℃ | -30 to 50 |
Pressure range | kPa | 80 to 120 |
Humidity range | % rh continuous | 15 to 90 |
Storage period | months @ 3 to 20℃ (stored in sealed pot) | 6 |
Load resistor | Ω (recommended) | 10 to 47 |
Weight | g | <13 |
Matched Transmitter board for CO-BX CO Sensor
4-20mA Analogue Transmitter Board
• Factory calibration, custom-set for immediate use
• Wide operating voltage range
• Low RFI susceptibility
Alphasense 4-20 mA analogue transmitter boards provide a cost effective way for Original Equipment Manufacturers to engineer transmitter heads for fixed installation systems.
4-20 mA Digital Transmitter Board
• Factory calibration, custom-set for immediate use
• Digital zero, sensitivity and temperature compensation
• Digital and 4-20mA output
• Biased or unbiased operation
• Calibration and range change