MT160  Ultrasonic thickness gauge

MT160 Ultrasonic thickness gauge

USD $300 - $400 /Set

Min.Order:1 Set

Supply Ability:
2000 Set / Sets per Month
Port:
FOB CHENGDU
Payment Terms:
T/T L/C Credit Card PayPal Other
Delivery Detail:
2 days

Quick Details View All >

Place of Origin:
China
Model Number:
MT160
Usage:
Other, thickness gauge

Chengdu Qifeng Technology Co., Ltd

Business Type: Manufacturer
Chengdu Sichuan China
Main Products: protable hardness tester ,benchtop hardness tester ,Non-destructive flaw detector ,Surface measuring instrument ,thickness gauge , spectrometer ,metallographic microscope ,universal testing machine

Product Details

MT160 Ultrasonic thickness gauge




Product Overview


Overview

The model MT160 is a digital ultrasonic thickness gauge .Based on the principle of ultrasonic principle, the instrument is capable of measuring the thickness of various materials, such as metal, plastic, ceramic, glass and many other good ultrasonic conductors. It of all kinds of materials. Compared with the traditional measurement methods, the advantages of ultrasonic thickness gauge is exposed to one side of the workpiece to complete the measurement. Its unique non-destructive testing performance provide the perfect solution for the thickness testing of closed pipes, containers, etc. It is widely used in pertroleum , chemical ,metallurgy, shipbuilding, aviation, aerospace and other fields because of monitoring corrosion thinning degree of various pipes and pressure vessels. It can also be used for precise measurement of sheet metal and machined parts.

Technical Parameters

Display

4.5 digits LCD with   EL backlight

Measuring Range

(0.75300)mm (in   Steel)

Sound   Velocity Range

                      (1000~9999)   m/s

Resolution

0.1mm/0.01mm

Accuracy

±0.5%Thickness+0.04mm,   depends on materials and conditions

Units

Metric/Imperial unit   selectable

Measurement Frequency

Four measurements   readings per second for single point measurement, and ten per second for Scan   Mode

Storage

Memory for up   to 20 files (up to 99 values for each file) of stored values

Thickness Measurement   Modes

Single point   thickness measurement and scanning thickness measurement

Power Source

Two “AA” size, 1.5   Volt alkaline batteries

Operating Time

More than 100 hours   (EL backlight off)

Communication

USB1.1(Can   communicate with PC )

Outline Dimension

150mm×74mm×32 mm

Weight

245g

 

 

Features

l  Suitable for measuring metal (such as steel, cast iron, aluminum, copper, etc.) , plastics, ceramics, glass, fiber glass and any other good ultrasonic conductors;

l  Dual straight beam probes with different frequencies and crystal sizes are available;

l  Zero calibration, two-point calibration, automatic error correction system;

l  Known thickness, sound speed can be measured, in order to improve the measurement accuracy;

l  Coupling status indicator showing the coupling status;

l  EL backlight for easy use in dimly lit environments;

l  Remaining battery indicator can display the remaining power in real time;

l  Auto sleep and auto power off function to conserve battery life

l  Small, portable, high reliability for harsh operating environment, anti-vibration, anti-shock and anti-electromagnetic interference.

Working Principle

The digital ultrasonic thickness gauge determines the thickness of a part or structure by accurately measuring the time required for a short ultrasonic pulse generated by a transducer to travel through the thickness of the material, reflect from the back or inside surface, and be returned to the transducer. The measured two-way transit time is divided by two to account for the down-and-back travel path, and then multiplied by the velocity of sound in the material. The result is expressed in the well-known relationship.

 

Where

HThickness of the test piece.

vSound Velocity in the material.

tThe measured round-trip transit time.

 

To make sure the probe working properly, it needs to use couplant to isolate the air between the probe surface and the measured workpiece surface. The liquid used for the coupling between the probe and workpiece is called as couplant.

 

 

 

 

 

Transducer Selection

Model

Freq

Diam

Measuring Range

Lower limit

Description

N05

5MHz

10mm

1.2mm-230mmIn Steel

Φ20mm×3.0mm

Normal measurement

N05/90°

5MHz

10mm

1.2mm-230mmIn Steel

Φ20mm×3.0mm

Normal measurement

N07

7MHz

6mm

0.75mm80.0mmIn Steel

   Φ15mm×2.0mm

For thin pipe wall or   small curvature

pipe wall measurement

HT5

5MHz

12mm

3.0200mmIn Steel

30mm

For high temperature   (lower than

300℃) measurement.

N02

2.5MHZ

 

14mm

 

3.0mm300.0mmIn Steel

Under 40mm (HT200)

20mm

For thick, highly   attenuating, or

highly scattering   materials

Configuration

Standard

Configuration

No.

Item

Quantity

Note

1

Main body

1


2

Probe: N05

1


3

Couplant

1


4

Instrument Case

1


5

Operating Manual

1


6

Alkaline battery

2


Optional

Configuration

1

Probe: N05/90°(5MHz)



2

Probe: N02(2.5MHz)



3

Probe: N07(7MHz)



4

Probe: HT5(5MHz)



5

High temperature   couplant



6

USB Cable



7

DataPro Software



 


Contact Supplier

Ms. Cindy Lee sales manager Chat Now
Telephone
86-28-68029098
Mobile
86-18302800987
Fax
86-28-68029098
Skype
cindy@cdqfkj.com
Address
Hongqi Road,PiXian Chengdu,Sichuan

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Measurement & Analysis Instruments > Testing Equipment
Categories
Hi~