Automatic large volume high capacity pressure autoclave steam sterilizer
Usage and Application
This horizontal steam sterilizer apply gravity replacement to remove the cold air of inner chamber,
which reduce the steam cold air and make sterilizing reliable. At the same time, during the sterilizing
process, the control system of the equipment can automatically adjust the steam inlet and outlet
according to the internal temperature. This equipment is used for sterilization of medical and experimental
cloth articles, surgical instruments and utensils in hospital supply room, operating room, pharmaceutical
factory and R&D institution laboratory.
Characteristics:
1. Sterilizing course automatic sterilization controlled,easy to operate.
2. With drying function,suitable dressing drying.
3. With over-temperature,over-pressure auto-protect device.
4. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
6. The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.
7. Fully stainless steel structure.
Technical data
This horizontal steam sterilizer apply gravity replacement to remove the cold air of inner chamber,
which reduce the steam cold air and make sterilizing reliable. At the same time, during the sterilizing
process, the control system of the equipment can automatically adjust the steam inlet and outlet
according to the internal temperature. This equipment is used for sterilization of medical and experimental
cloth articles, surgical instruments and utensils in hospital supply room, operating room, pharmaceutical
factory and R&D institution laboratory.
Characteristics:
1. Sterilizing course automatic sterilization controlled,easy to operate.
2. With drying function,suitable dressing drying.
3. With over-temperature,over-pressure auto-protect device.
4. The door opening mechanism cannot be operated until the pressure in the chamber is reduced to 0.027MPa.It can't be start on if the door doesn't close well.
5.The safety value will be open automatically when the inner pressure over 0.24MPa,and the steam be exhausting to the water tank.
6. The power will be cut-off automatically,cut-off the water and alarm when the machine lacking water.
7. Fully stainless steel structure.
Technical data
Technical data | WS-150YDC | WS-200YDC | WS-280YDC | WS-400YDC |
Sterilizing chamber Volume | 150L φ440×850mm | 200L φ515×1000mm | 280L φ600×1000mm | 400L φ700×1100mm |
working pressure | 0.22MPa | |||
working temperature | 134ºC | |||
Adjustment of temperature | 40ºC- 134ºC | |||
Time of sterilization | 0-99 min | |||
Time of drying | 0-99 min | |||
Heat average | ≤±2ºC | |||
Power | 9KW/380V 50Hz | 9KW/380V 50Hz | 12KW/380V 50Hz | 18KW/380V 50Hz |
Dimension | 1400×600×1300 | 1400×670×1650 | 1400×770×1780 | 1430×880×1830 |
Transport dimension | 1550×750×1850 | 1560×820×1850 | 1680×920×2100 | 1600×1050×2100 |
G.W/N.W | 320/240 KG | 350/260 KG | 465/365 KG | 530/420 KG |
Other types