Operating Room MRI Anesthesia Machine Manufacturer for Sale
USD $1 - $3000 /Unit
Min.Order:1 Unit
Zhengzhou Medbes International Trading CO., LTD.
Excellent quality medical anesthesia ventilator machine
This high-precision vaporizer is designed with a stable concentration output, automatic compensation for pressure, temperature and flow rate. And it is available to choose one kind of gas from Halothane, Enflurane, Isoflurane, and Sevoflurane, ensuring a successful anesthesia operation.
Reliable pneumatic transmission system.
Economic and proper configuration of technologies, optional as required by the customer.
Modularized design and upgrading. Upgrading is available as required by the customer.
Anesthesia Machine | ||||||||
Model | YJ-A800 | YJ-A801 | YJ-A802 | YJ-A803 | YJ-A804 | YJ-A805 | ||
Part of Anesthesia Machine | ||||||||
Main body | High-strength engineering plastic rack, light, beautiful and corrosion resistan | |||||||
Scope of application | adult, child(4 years above) | |||||||
Gas source | O2:0.28~0.6 MPa | O2, N2O: 0.28~0.6MPa | O2, N2O, Air: 0.28~0.6MPa | |||||
Flow meter | O2: n1.0-10L/min | O2: 0.051.0L/min 1.1-10L/min | O2,N2O: 0.0510L/min 0.05-10L/min | O2,N2O: 0.05-1.0L/min 1 .1-10L/min | O2,N2O: 0.05-1.0L/min 1.1-10L/min | O2,N2O: 0.05-1.0L/min 1.1-10L/min Air:0. 05-10L/min | ||
O2,N2O linkage and N2O Stopper | / | / | When using nitrous oxide, oxygen concentration>25%. When the oxygen pressure<0.2MPa, the flow of nitrous oxide would be cut off. | |||||
Vaporizer | one | One, high-precision evaporator | One, high-precision evaporator | One, high-precision evaporator | Two, high-precision evaporator | Two,high-precision evaporator | ||
Part of Ventilator
| ||||||||
Display mode | / | 5.7” | 5.7” | 10.4” TFT | 5.7” | 10.4” TFT | ||
mode | / | IPPV, SIPPV, SIMV, MANUAL | IPPV,SIPPV, SIMV, MANUAL | IPPV, SIPPV, SIMV,MANUAL, VCV, PCV | IPPV,SIPPV,SIMV, MANUAL | IPPV, SIPPV, SIMV,MANUAL, VCV, PCV | ||
function | / | PEEP, SIGH, IRV | PEEP, SIGH, IRV | PEEP,SIGH, IRV, IP, standby | PEEP, SIGH, IRV | PEEP,SIGH, IRV, IP, standby | ||
TV | / | 50~1500ml | 50~1500ml | 20~1600 ml | 50~1500ml | 20~1600 ml | ||
Rate | / | 2~99 bpm | 2~99 bpm | 2~99 bpm | 2~99 bpm | 2~99 bpm | ||
SIMV rate | / | 2~20 bpm | 2~20 bpm | 2~20 bpm | 2~20 bpm | 2~20 bpm | ||
I:E | / | 2:1~1:8 | 2:1~1:8 | 4:1~1:8 | 2:1~1:8 | 4:1~1:8 | ||
Inspiratory trigger pressure | / | 10~20cmH2O | -10~20cmH2O | -10~20cmH2O | -10~20cmH2O |
-10~20cmH2O | ||
PEEP | / | 2~20cmH2O | 2~20cmH2O | 2~20cmH2O | 2~20cmH2O | 2~20cmH2O | ||
Pressure limitation | / | 10~60cmH2O | 5~60 cmH2O | 10~60cmH2O | 5~60 cmH2O | |||
SIGH | / | 1.5 times the inspiratory time/100bpm | SIGH 1.5 times the inspiratory time (60-120 adjustable) | 1.5 times the inspiratory time/100bpm | IGH 1.5 times the inspiratory time (60-120 adjustable) | |||
Inspiratory platform | / | / | / | 0~50% | / | 0~50% | ||
Pressure control | / | / | / | 3~50 cmH2O | / | 3~50 cmH2O | ||
Power | / | AC 220V 50Hz (UPS, Storage battery) | ||||||
Parameters for ventilation monitoring | / | B1, B2, B4: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow - time waveform, PEEP, inspiratory trigger pressure B3, B5: tidal volume, minute ventilation volume, IPPV rate, SIMV rate, total respiratory rate, I/E, peak pressure of airway, pressure - time waveform, flow rate - time waveform, PEEP, inspiratory trigger pressure, inhale tidal volume, inspiratory platform, average pressure, autonomous inspiratory rate, oxygen concentration, battery capacity, flow-volume loop, pressure-volume loop | ||||||
Mechanical Arms | / | / | / | YES | YES | YES | ||
End-tidal CO2monitoring | Optional |
Technical parameters
Part of Anesthesia | ||
Main body | High-strength engineering plastic rack, light, beautiful | |
Scope of application | adult, child | |
Gas source | O2: 0.28~0.6MPa | N2O: 0.28~0.6MPa |
Flow meter | O2 : 0.05~10L/min | N20: 0.05~10L/min |
O2 N2O linkage and N2O Stopper | When using nitrous oxide, oxygen concentration>25%; | |
When the oxygen pressure<0.2Kpa, the flow of nitrous | ||
Flow rate of rapid | 25~75L/min | |
Low oxygen pressure alarm | There will be sound alarm when the oxygen pressure | |
Vaporizer | It has the function of automatic compensation based on | |
Respiratory circuit | working mode: all-close, semi-close, semi-open | |
APL≤12.5 kPa | ||
Respiratory Bellows | bellows for adults, tidal volume range:0~1500 ml | |
bellows for children, tidal volume range:0~300 ml | ||
anyone can be chosen for application as required by | ||
Display mode | High-definition 5.7” LCD screen display | |
Part of Ventilator | ||
Ventilation mode | IPPV, SIPPV, SIMV, MANUAL | |
Ventilation functions | PEEP,SIGH, IRV | |
Ventilation parameters | Tidal volume | 50~1500 ml |
Rate | 2~99 bpm | |
SIMV rate | 2~20 bpm | |
I:E | 2:1~1:8 | |
Inspiratory trigger pressure | -10~20 cmH2O | |
PEEP | 2~20 cmH2O | |
Pressure range | 5~60 cmH2O | |
SIGH | 1.5 times the inspiratory time | |
Parameters for ventilation monitoring | Expired tidal volume, Inhale tidal volume, minute | |
Security Alarm System | ||
Airway pressure alarm | upper limit setting range 5~60 cmH2O | |
low limit setting range 0~50 cmH2O | ||
Per-minute ventilation volume alarm | upper limit setting range 1~20L/min | |
low limit setting range 0~19L/min | ||
Tidal volume | upper limit setting range 100~1500ml | |
low limit setting range 0~1400ml | ||
Sustained high-pressure alarm | it will give alarm when stress have consistently been | |
Power | AC 220V±10% 50Hz±1Hz(UPS, Storage battery) | |
Mechanical Arms | ||
(End-expiratory CO2 monitoring) | ||
(Specific interface of waste anesthesia gas) | ||
*Items within brackets are optional. |