30M3 LCO2 Cryogenic Liquid Storage Gas Tank 50M3 LCO2 Tank
USD $35669 - $63750 /Set
Min.Order:1 Set
10MT LPG skid tank Gas Station LPG Filling Plant LPG tank 20000L LPG Tank
Hot sell mobile LPG skid filling station 20m3 lpg filling plant for cylinder filling
Chemical plant use liquid oxygen tank nitrogen storage tank cryogenic tank
Stainless Steel 0.8 Mpa 20000 Liter Cryogenic Liquid Nitrogen Oxygen Argon LNG Tank
30M3 LCO2 Cryogenic Liquid Storage Gas Tank 50M3 LCO2 Tank
India 30m3 liquid carbon dioxide tank,cryogenic vacuum LCO2 storage tank
30M3 CO2 Tank with carbon steel made in heze boiler factory
Cryogenic liquid storage tanks is a series of products of producing first, second , third types of pressure vessel ,the products strictly in accordance with the GB150 "pressure vessels", GB18442-2011 stationary vacuum insulation cryogenic pressure vessel, and the fixed safety technical supervision type of pressure vessel to design,
manufacture,inspect and accept.
Cryogenic liquid storage tanks is for double wall, vertical (horizontal) structure, adopt the use of vacuum powder adiabatic, with the advantage of compact structure , low issuance date,small footprint,centralized control, safe,reliable, easy operation and maintenance.
Technical Parameters of Cryogenic Tank
Cryogenic Storage Tank Technical Parameter | |
Full Capacity | 31.58M3 |
Rated filling rate | 0.95 |
Valid capacity | 30 M3 |
Medium | LCO2 |
Design pressure | 2.2MPa |
Working pressure | 2.16MPa |
Max. Allowance working pressure | 2.27MPa |
Liner materials | 16MnDR |
Shell materials | Q345R carbon steel |
Weight in theory(kg) | 18170 |
Inner specification | DN2400*6100 |
Shell Specification | DN2900*6780 |
Outline Dimension (mm) | Φ2920*8914 |
Design using life | 20 years |
Insulation form | Vacuum Powder |
Remark: The mentioned parameters of LCO2 tank is subject to the drawing. |
Related Rules & Standards of Cryogenic Tank
1.TSG 21-2016< Fixed rules of the safety technique pressure vessels>
2.GB150.1~150.4-2011
3.NB/T47014-2011
4.NB/T47015-2011
5. GB/T25198-2010
6.JB/T4730-2005
7.NB/T47016-2011
8. JB/T4711-2003
9. GB/T18442.1-18442.6-2011 < Stationary vacuum insulated cryogenic pressure vessels>
Inspection, Test and Acceptance of Low Temperature Tank
1.After inspection of inner cylinder material to make sure it is qualified, and then put into use.
2.Check all weld joint according to GB150.1~150.4-2011 standard, after inspection passed, A and B type weld joint need 100% ray test, C and D type weld joint 100% dye test and issue the test report.
3.After installation of the shell, there will be a test according to GB150.1~150.4-2011 standard for checking of geometric dimension, nozzle orientation and shape deviation.
4.Inspection after pressure test and pressure test report issued, after pressure test of pumping air into vacuum state, after vacuum degree requirements helium leak test.
5.After interlayer leak detection qualified fill perlite in vacuum, vacuum degree meet the requirements of GB/T18442-2011 standard then sealed-off vacuum degree.
6.After tank manufacturing has been completed, the seller notify the buyer to the seller's site for pre-acceptance, acceptance of the project including tank vacuum degree index, the valve instrument configuration, exterior paint quality, whether the factory documents is complete, after the acceptance of the buyer, the seller can deliver goods after signed by both sides.