Energy Release 2pairs - 91pairs Yellow Marine Electrical Cable
Negotiable
Min.Order:0
Shanghai DingBai Wire & Cable Co., Ltd
Cable Hydraulic Rating:
Water pressure classification | The following are the same as the Resistant to vertical hydraulic capacity | The following are the same as the Resistant to horizontal hydraulic capacity | |||
Water pressure rating | 4.5MPa | 6.0MPa | 10.0MPa | 10.0MPa | 70.0MPa |
Single core | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area of 0.12mm² -16mm² . Conductor stranded with water blocking glue. | Multi-strand tinned copper wire or silver-plated copper wire stranded conductor, conductor cross-sectional area of 0.035mm² -16mm² . | |||
Multiple core lines | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area of 0.12mm² -16mm² , twisted pair: 2 pairs of -91 pairs.
| Multi-strand tinned copper wire or silver plated copper wire stranded conductor, conductor cross-sectional area of 0.035mm² -16mm² , core number: 2 core -91 core. | |||
Many pairs of core | Multi-strand tinned copper wire stranded conductor, conductor cross-sectional area of 0.12mm² -16mm² , twisted pair: 2 pairs of -91 pairs. | Multi-strand tinned copper wire or silver-plated copper wire stranded conductor, conductor cross-sectional area of 0.035mm² -16mm² , the number of cores: 2 pairs of -91 pairs, shielding form: | |||
Operating temperature | -50℃-80℃ | ||||
Short temperature | Resistant to 130 ℃, 2h low temperature vulcanization of 3m vulcanized rubber | ||||
Sheath material | Polyurethane, rubber | ||||
Resistant to seawater | Be applicable | ||||
Underwater robot cable test standard | GJB1916-94,GJB774-1989,MIL-DTL-24643 |
Specification:
ROV Tethers include power conductors, shielded data pairs and video using coax, TSP, or fi ber optics. Designs available in several confi gurations, including Neutral Buoyancy.A varied degree of strength designs available depending on workloads and handling system.
Description:
The cable is mainly used for electrical connection between devices and requires work in an underwater environment. According to the signal transmission requirements, the signal control line can be multi-stranded single-core, multi-core, many pairs of different combinations of the core composition; according to the isolation requirements, shielding forms can be individually single shield, separate 2 layer shield, single Layer total shielding, 2 layers of the total shielding, etc .; according to the use requirements, can be vertical underwater robot cable form, horizontal seal form.
Vertical underwater cable: for the ship to wear a warehouse connection, high reliability of the use of the environment. Requires the cable end (axial) to withstand water pressure, in the eng_provisions of the test pressure and time, not allowed to water seepage.
Horizontal underwater cable: non-wear underwater use of the environment. Requirements cable jacket (radial) to water pressure, in the eng_provisions of the test pressure and time, the cable insulation resistance does not decline, the cable is not deformed.