HCL-A1 Hydrogen Chloride (HCN) Sensor

HCL-A1 Hydrogen Chloride (HCN) Sensor

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
5000 Piece / Pieces per Month
Port:
HK
Payment Terms:
T/T PayPal
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Alphasense
Place of Origin:
United Kingdom
Model Number:
HCL-A1
Usage:
Gas Sensor
Theory:
Other, Electrochemical Gas Sensor

Shenzhen Isweek Ltd.

Business Type: Distributor/Wholesaler
Main Products: Gas Sensor ,UV Sensor ,Humidity Sensor ,Pressure Sensor ,Ultrasonic Sensor ,Wind Speed sensor ,Liquid Level Sensor

Product Details

HCL-A1 Hydrogen Chloride Sensor HCL Sensor Description
Alphasense is expanding its line of electrochemical 
Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs.

Hydrogen Chloride (HCl)/Hydrogen Bromide (HBr)
The HCL sensor also detects Hydrogen Bromide (HBr). These HCL sensors are zero biased for easier use.
Available in A and B series.


HCL-A1 Hydrogen Chloride Sensor HCL Sensor Schematic Diagram

 

HCL-A1 Hydrogen Chloride Sensor HCL Sensor PERFORMANCE
Sensitivity
nA/ppm in 25ppm HCl
80 to 130
Response time
t90 (s) from zero to 25ppm HCl
<300
Zero current
ppm equivalent in zero air
<±2.5
Resolution
RMS noise (ppm equivalent)
<1
Range
ppm HCl limit of performance warranty
100
Linearity
ppm error at full scale, linear at zero, 40ppm HCl
0 to 6
Overgas limit
maximum ppm for stable response to gas pulse
200



HCL-A1 Hydrogen Chloride Sensor HCL Sensor LIFETIME
Zero drift
ppm equivalent change/year in lab air
nd
Sensitivity drift
% change/year in lab air, monthly test
nd
Operating life
months until 80% original signal (12 month warranted)
nd



HCL-A1 Hydrogen Chloride Sensor HCL Sensor ENVIRONMENTAL
Sensitivity @ -20°C
% (output @ -20°C/output @ 20°C) @ 25ppm HCl
65 to 90
Sensitivity @ 50°C
% (output @ 50°C/output @ 20°C) @ 25ppm HCl
102 to 120
Zero @ -20°C
ppm equivalent change from 20°C
<0 to 4
Zero @ 50°C
ppm equivalent change from 20°C
<+1 to -5



HCL-A1 Hydrogen Chloride Sensor HCL Sensor CROSS SENSITIVITY
H2S  sensitivity
% measured gas @ ppm H2S
<250
NO2  sensitivity
% measured gas @ ppm NO2
<-150
Cl2    sensitivity
% measured gas @ ppm Cl2
<-20
NO    sensitivity
% measured gas @ ppm NO
<2
SO2  sensitivity
% measured gas @ ppm SO2
<0.1
CO     sensitivity
% measured gas @ ppm CO
<0.1
H2     sensitivity
% measured gas @ ppm H2
<0.1
C2H4 sensitivity
% measured gas @ ppm C2H4
<0.1
NH3  sensitivity
% measured gas @ ppm NH3
<0.1
CO2 sensitivity
% measured gas @ 5% CO2
<0.1



HCL-A1 Hydrogen Chloride Sensor HCL Sensor KEY SPECIFICATIONS
Temperature range
°C
-30 to +50
Pressure range
kPa
80 to 120
Humidity range
% rh continuous
15 to 90
Storage period
months @ 3 to 20°C (stored in original container)
6
Load resistor
Ω (recommended)
10 to 33
Bias voltage
mV 
not required
Weight
g
<6


Contact Supplier

Ms. Ms Rita yu Sales Chat Now
Telephone
86-755-83289036
Mobile
86-15216024218
Fax
86-755-83289052
Skype
Isweek_Rita
Address
16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors