ASTM A335 P92 is the part of ASTM A335, The pipe shall be suitable for bending, flanging, and similar forming operations, and for fusion welding. The steel material shall conform to chemical composition, tensile property, and hardness requirements.
Each length of pipe shall be subjected to the hydrostatic test. Also, each pipe shall be examined by a non-destructive examination method in accordance to the required practices. The range of ASTM A335 P92 seamless alloy steel pipe sizes that may be examined by each method shall be subjected to the limitations in the scope of the respective practice.
The different mechanical test requirements for pipes, namely, transverse or longitudinal tension test, flattening test, and hardness or bend test are presented.Both ends of each crate will indicate the order no., heat no., dimensions, weight and bundles or as requested.
Chemical Requirements of ASTM A335 P92
UNS Designation | K92460 |
Carbon | 0.07–0.13 |
Manganese | 0.30–0.60 |
Phosphorus(max) | 0.02 |
Sulfur(max) | 0.01 |
Silicon | 0.50 max |
Chromium | 8.50–9.50 |
Molybdenum | 0.30–0.60 |
V | 0.15-0.25 |
N | 0.03-0.07 |
Ni (max) | 0.4 |
Al(max) | 0.02 |
Cb | 0.04-0.09 |
W | 1.5-2.00 |
B | 0.001-0.006 |
Ti (max) | 0.01 |
Zr(max) | 0.01 |
Mechanical Properties of ASTM A335 P92
Tensile strength, min, (MPa) | 620 |
Yield strength, min, (MPa) | 440 |
Elongation, min, (%), L/T | 20/… |
Material & Manufacture
Pipe may be either hot finished or cold drawn with the finishing heat treatment noted below.
Heat Treatment
Mechanical Tests Specified of ASTM A335 P92
Transverse or Longitudinal Tension Test and Flattening Test, Hardness Test, or Bend Test
For material heat treated in a batch-type furnace, tests shall be made on 5% of the pipe from each treated lot. For small lots, at least one pipe shall be tested.
For material heat treated by the continuous process, tests shall be made on a sufficient number of pipe to constitute 5% of the lot, but in no case less than 2 pipe.
Permitted tolerance for OD
OD | Plus tolerance(+) | Minus tolerance (-) |
10.29—48.3 | 0.4 | 0.4 |
<48.3—-≤114.3 | 0.79 | 0.79 |
<114.3—≤219.1 | 1.59 | 0.79 |
<219.1—≤323.9 | 2.38 | 0.79 |
<323.9 | ±1% |