FS7002 Series MEMS Mass Flow Sensors Description

FS7002 series mass Flow sensors can be used for open air space flow measurement or applied for clog sensing in an open space configuration. The sensor can measure air flow up to 10 m/sec with a fast response. The compact design make the installation an easy task. Examples are clog sensing in LCD projector; HVAC air flow monitoring, air fresher and fan status monitoring.

FS7002 Series MEMS Mass Flow Sensors Features and Applications
- Measure open space air flow up to 10 m/sec
- Fast response<20 msec
- Compact miniature design
- Excellent sensitivity
- Bi-direction capability
- Additional customization available

FS7002 Series MEMS Mass Flow Sensors Mechanical Dimensions


FS7002 Series MEMS Mass Flow Sensors Specifications

All data unless otherwise noted apply for measurement conditions: air, 20 °C, 101.325 kPa absolute pressure, in a fixed flow channel of 8mm in diameter.

Model
FS7002-B
FS7002-C
Unit
Flow range
0 ~ 5
0 ~ 10
m/s
Repeatability
± 3
± 2
%FS
Response Time
20ms
Output
Non-linear, Analog

Null Output1
0.2 ~ 0.8
Vdc 
Full Scale Output1
2.5 ~ 3.3
Vdc
Power Supply
5 ± 5%
Vdc
Operating Current2
<10
mA
Power Consumption
<50
mW
Output Load
Sourcing: 14; Sinking: 11
mA
Pins Out
3 Pin, 2.54 mm centers, 0.635 mm square

Working Temperature
-10 ~ +70

Storage Temperature
-20 ~ +80
Humidity
<95 %RH(No icing or condensation)

1 To obtain accurate flow measurement, let the sensor warm up 1 minute at power up.
2 The operating current is measured at 5.0 V supply without output load.


Contact Supplier

Ms. Ms Rita yu Sales Chat Now
Telephone
86-755-83289036
Mobile
86-15216024218
Fax
86-755-83289052
Skype
Isweek_Rita
Address
16 Floor, Building #3, Zhongke Mansion, Gaoxin South 1st Rd, Hi-Tech Park, Nanshan Shenzhen,Guangdong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Electronic Components & Supplies > Active Components > Sensors
Categories
Hi~