Hydraulic Testing Gauge MYTH-1-5
1. Before starting the equipment, loading must be unscrewed (left screwing to the end). Otherwise, danger easy arises..
2. Near the loading valve is high-pressure oil inlet, the other is outlet. Loading will not be realized if the inlet and outlet are connected at wrong position.
3. Please shut off the power when the instrument not in use
4. This instrument is connected in series with the equipment system tested, and there should be no pressure in the oil outlet. Otherwise, the loading valve cannot screw.
5. When installing the oilinlet and oiloutlet mouths joint, make sure you use the spanner to position the six-party joint of cabinet, and then connect to the fittings body.
Oil outlet ,Oil inlet,Upper Display Screen(Display the instantaneous flow), Loading valve,Under Display Screen(Fluid temperature), Coefficient Modifying keys of testing gauges should not adjust rashly.
Technical Specifications
model |
Max flow (LPM) |
Max pressure(bar) |
Temperature |
Precision |
Dimension(mm) |
Weight(KGS) |
MYHT-1-2 |
200 |
420 |
150°C |
±1% |
295x265x210 |
6.1 |
MYHT-1-4 |
400 |
420 |
150°C |
±1% |
295x265x210 |
8.8 |
MYHT-1-5 |
500 |
420 |
150°C |
±1% |
295x265x210 |
10.2 |
MYHT-1-7 |
800 |
420 |
150°C |
±1% |
310x285x261 |
14 |