MYHT hydraulic tester-1-5
Negotiable /Piece
Min.Order:1 Piece
MYHT hydraulic tester-1-5
MYHT series hydraulic pressure tester use and maintenance:
This section is only general instruction. Relevant information provided by the manufacturer must be referred and specific systems such as Variable Pump or Motor or Serve Control Vale have specific test program.
When MYHT - 1 Hydraulic Tester is installed at any position of hydraulic pipe, the hydraulic oil always flows from near the loading valves to the other end. If reverse connect arises, no pressure will be formed. In order to obtain the accurate measurements, the oil inlet and oiloutlet of the tester keep away above30cm away from the elbow, tees, valve.
Note: The loading valve must be unscrew counterclockwise before start-up of the equipment. It will cause human injury or equipment damage if the loading valve is fully closed!!!!!!
Once the tester accessed with oil pipeline, the pressure will be regulated by Loading Valve.
1) Frigid climate will influence on the accuracy of measurement, so oil should be cycled some time before test. Until the the temperature goes up to 30°C, the test shall be conducted.
After the completion of test, power switch should be turned off.
Open Pressure Loading Valv on test
Maintenance instructions
In the design, MYHT Series Hydraulic Pressure Tester is a device that can be used for many years and with less trouble, If trouble arises after the quality guarantee period, it is available to do some simple inspection.
Loading Valve
If the Loading Valve can't load the system, remove the alve spool and check if there are impurities on it or worn-out parts or or damages on seal ring.
Battery
The batteries for the meters are 12V lithium battery. Charge 4-8 hours before the tester work, and the battery can be used for 30 hours. It is necessary to charge the batteries with supporting charger, otherwise, explosion danger will easily arise.