Multi-link filter press

Multi-link filter press

Negotiable /Piece

Min.Order:1 Piece

Supply Ability:
0 Piece / Pieces per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Qingdao Senxin Group Co.,Ltd

Business license
Business Type: Trading Company
Laiwu Shandong China
Main Products: drilling fluid testing equipments ,oil well cement testing equipments , slurry testing equipment ,roller oven ,API filter press ,drilling fluids viscometer ,EP lubricity tester ,HTHP filter press ,HTHP consistometer ,Pressure mud balance ,LPLT filter press ,retort kit

Product Details

Specifications & size: SD3;SD4;SD6;SD6A
Technical parameters: Article name:three link water loss apparatus Specifications & size:SD3 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long three link Overall size:650×200×500 article name:four link water loss apparatus Specifications & size:SD4 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long four link Overall size:960×200×500 article name link water loss apparatus Specifications & size:SD6 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long six link;round six link Overall size:1480×200×500 article name:six link water loss apparatus Specifications & size:SD6A Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long six link;Stainless cup attached Overall size:1480×200×500
Purpose & characters:The apparatus is used to measure the static water loss of drilling fluid under a certain pressure within a certain time. At the same time, it can also measure mud cake after the water loss. Multi-link water loss apparatus can do several experiments at the same time and improve teh efficacy.
Specifications & size: GGSD71
Technical parameters:
 Power supply:220V±5% 50Hz
Power:1.2KW
Speed adjustment ranging:0-800 r/min
Air supply: Azote safe work pressure of drilling well room: 8.5MPa
 
Safe work pressure of return pressure room:5 MPa
Drilling fluid Cup capacity: 500ml
Return pressure receiver capacity:95ml
Overall size:400×250×700
Purpose & characters: HTHP dynamic water loss meter(dynamic filter press) measure the water loss of drilling fluid and cement slurry in the simulant downhole operation condition (hthp) and supplies data for the realization of scientific, quick, high quality and safe well drilling.
 
It is applicable to:from room temperature to 232℃;
Max Working pressure in drilling fluid room ≤7.1MPa;filter loss differential pressure: 3.5MPa;
Filter loss area: 22.6cm2;collected static water loss and formed filter cake thickness within 30 minutes. The temperature scope: from room temperature to 150℃;
Max working pressure in drilling fluid room ≤7.1MPa;filter loss differential 3.5MPa;
Filter loss area: 22.6cm2;colleted dynamic water loss and fromed filter cake thicknes within 30 minutes. Two layers mesh screen can satisfy the measurement for cement slurry.
 

Specifications & size: GGS71-A
Technical parameters:

Max working pressure : 232℃ Slurry cup

 Working pressure: 7.1MPa

Filter loss area : 22.6cm2 Slurry

Cup capacity : 500ml.

Repetitive error:<2ml

Overall size:305×205×640

Purpose & characters:HTHP filter press(water loss meter) adopts American technology to stimulate the water loss speed of drilling fluid in the condition under deep well (hthp). It is the necessary analytical measuring instrument for the scientific research in all oil fields and research institutions. It has the characters of steady function and small repetitive error. Adopting two layors of mesh screen can satisfy the measurement of cement mud.

 

Specifications & size: GGS42-1; GGS42-2
Technical parameters: Working temperature:150℃ Working pressure:4.2MPa Filter loss area:22.6cm2 Repetitive error:<2ml Cup capacity:250ml Overall size:150×200×400
Purpose & characters:HTHP filter press(water loss meter) is used to measure the water loss of drill fluid and mud cake thickness after water loss in the condition of HTHP. It is widely used in all oil fields, scientific reseach institutions, laboratories and other departments and has the characters of simple operation, high accuracy and small repetitive error. Adopting two layers of mesh screen can satisfy the measurement of cement mud.

 

Specifications & size: ZNS-2;ZNS-2A;ZNS-5A(API)
Technical parameters: Specifications & size:ZNS-2 Filter loss area:45.6cm2 Working pressure:0.69MPa Repetitive error:<1.5ml Configuration: Inflator air supply attached Overall size:200×150×400 Specifications & size:ZNS-2A Filter loss area:45.6cm2 Working pressure:0.69MPa Repetitive error:<1.5ml Configuration:stage form;Stainless cup attached Overall size:200×150×400 Specifications & size:ZNS-5A Filter loss area:45.6cm2 Working pressure:0.69MPa Repetitive error:<1.5ml Configuration:stage form;Amirican API standard Overall size:240×200×500
Purpose & characters: Medium pressure filter press,water loss meter is mainly used to measure the water loss and mud cake thickness of drilling fluid after the loss of water. It is widely used in all the big oil fields, oil fields exploration and analysis as well as measurement of drilling fluid in the laboratory. It has the characters of simple operation, convenient use, good stability and small repetitive error in water loss measure.

 

Specifications & size: SD3;SD4;SD6;SD6A
Technical parameters: Article name:three link water loss apparatus Specifications & size:SD3 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long three link Overall size:650×200×500 article name:four link water loss apparatus Specifications & size:SD4 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long four link Overall size:960×200×500 article name link water loss apparatus Specifications & size:SD6 Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long six link;round six link Overall size:1480×200×500 article name:six link water loss apparatus Specifications & size:SD6A Filter loss area:45.6cm2 Working pressure:0.69MPa filter time:30min Configuration:long six link;Stainless cup attached Overall size:1480×200×500
Purpose & characters:Multi-link water loss meter(filter press) is used to measure the static water loss of drilling fluid under a certain pressure within a certain time. At the same time, it can also measure mud cake after the water loss. Multi-link water loss apparatus can do several experiments at the same time and improve teh efficacy.

Contact Supplier

Ms. Mr Frank Xu manager Chat Now
Telephone
86-158-98857061
Mobile
86-15898857061
Fax
86-158-89052676
Skype
86-15898857061
Address
Hubei Road,Jiaonan,Qingdao city,China Laiwu,Shandong