Power consumption: 280mW typical
Default output range:
Voltage mode: 0.4V – 2.0V
Pellistor mode: 0 – 100mV from mid supply relative to detector pin
Response time (T90) < 30s
Warm up time:
To operation < 60s
To specification < 30 minutes
Nominal ranges: 0 – 5% volume methane
0 – 100% LFL hydrocarbons
0 – 100% volume methane
Minimum resolution:
At zero < 0.5% of range
At range <2% of range
Zero repeatability: ± 1% of range
MTBF > 5 years
Weight: 18.0 grams
Vibration: Complies with EN61779-1
Relative humidity: 0 – 95% RH non-condensing
Operating temperature range: -30°C to +55°C
Operating pressure range: 700 – 1300 hPa
Storage temperature range: -40°C to +80°C
Supply voltage range: 3.0V – 5.0V