Hinge Door Pass Through Large Steam Sterilizer For BSL3 / BSL4 Laboratories
Key Features:
Chamber volume from 800 to 8000 Liters User-friendly HMI Thermal sterilization treatment sterilizes all effluent and waste water Double or single filtration systems ensure air is decontaminated before discharge Double door pass-through autoclave Autoclave chamber, piping and fittings are made from 304 stainless steel Interlocks protect against passage of contaminated materials Bio-shield barrier hermetically seals between the differently qualified zones Double door pass-through autoclave Hinge door with automatic locking Minimal media consumption SIP and integrity testing portDescription:
In today’s society the need for safe bio-containment systems is increasingly important.
This is especially true in the sterilization process where standard autoclaves cannot deal
with the threat posed by harmful pathogens and other contaminated materials that are emitted
from BSL3/4 laboratories.
Specifications:
Model |
Chamber Size |
Overall Size |
Steam |
Water |
Power |
W*H*D mm |
W*H*D mm |
Kg/cycle |
Kg/cycle |
KVA |
|
MDL-0.8 |
610*910*1450 |
1500*1900*1790 |
35 |
280 |
3 |
MDL-1.0 |
680*1180*1250 |
1600*2000*1590 |
40 |
300 |
4 |
MDL-1.2 |
680*1180*1500 |
1600*2000*1840 |
45 |
320 |
4 |
MDL-1.5 |
680*1180*1870 |
1600*2000*2210 |
50 |
350 |
4.5 |
MDL-2.0 |
1000*1200*1700 |
2000*2000*2040 |
60 |
400 |
4.5 |
MDL-3.0 |
1000*1500*2000 |
2000*2200*2340 |
90 |
500 |
5 |
MDL-4.0 |
1000*1500*2670 |
2000*2200*3010 |
120 |
600 |
6 |
MDL-5.0 |
1000*1500*3340 |
2000*2200*3680 |
150 |
700 |
8 |
MDL-6.0 |
1000*1500*4000 |
2000*2200*4340 |
180 |
800 |
8 |
MDL-8.0 |
1000*1500*5340 |
2000*2200*5680 |
240 |
1000 |
12 |
Our Advantages:
The Large Steam Sterilizer is designed to process laboratory animal caging systems and associated equipment. Developed with the sustainable laboratory in mind, the sterilizer incorporates several features to maximize productivity, provide flexibility, and ensure safety and reliability.
Productivity
Sizes range from 0.8 cubic meters to 8 cubic meters , allowing for a full range of load sizesFlexibility
Full range of programs and options to manage vivariums and BSL 3 & 4 application Decontamination Cycles using either 0.22 micron filter Fully welded BioSeal suitable for BSL 3 & 4 applicationsSustainability
The large steam sterilizer comes with the following Energy and Water saving features:
Reliability
3