Impulse Voltage Generator Test , AC Peak Measures , Reference Impulse calibrator
USD $4 - $5 /Piece
Min.Order:1 Piece
HiWING Mechanical &Electrical Technology company
Impulse Voltage Generator for the extra high voltage testing base of China
AC Test Transformer For Insulation Tests On Insulation Materials , Structures
Impulse Voltage Generator for a high altitude testing station in Tibet
4000kV 600kJ Impulse Voltage Generator , high voltage pulse generator
4200kV / 200kJ outdoor High Impulse Voltage Generator test set
Safty reliable action Impulse Voltage Generator can be connected in parallel
voltmeters for impulse voltage generator test ,AC peak measures
Impulse voltage generator (a kind of high voltage generator of impulse wave, used to test the insulation performance of electrical equipment when subject to over voltage (lightning strike) in atmosphere.)
Impulse voltage generator is a kind of high voltage generator of impulse wave, used to test the insulation performance of electrical equipment when subject to over voltage (lightning strike) in atmosphere. The impulse voltage generators produced by the Company can be divided into L type and H type by structure, be divided into indoor fixed type, indoor air cushion type, outdoor fixed type and quick-mounting type by working environment and be divided into swinging arm type and stationary type by discharging manner.
AC peak voltmeter
Main features:
The FZG peak voltmeter is featured by automatic shift of measurement ranges, visualization of waveforms, display of tested voltages with preset divider ratio, and storage of values during disruptive discharge.
Technical parameters:
Application conditions: ambient temperature -10℃-50℃
relative humidity≤90%
Measurement quantities: AC sine wave peak value, peak/√2, true RMS
Frequency range: 0-1000Hz
Input voltage: 10V-1600VAC
Input impedance: ≥5MΩ
Divider ratio: 0.0-9999.9
Accuracy: <±1%
Display: LCD (voltage and waveform)
Power supply: 220V+10%
Impulse voltage peak voltmeter
The FZC impulse voltage peak voltmeter is used to measure single impulse voltages with front time over 840nS. It can also be used to measure and store peak values of impulse voltages, chopped impulse voltages, and other types of single impulse voltages.
Main features:
The FZC peak voltmeter is featured by automatic shift of measurement ranges, LCD visualization of tested voltages with preset divider ratio. It adopts special layout of standard industrial control bus.
Technical parameters:
Application conditions: ambient temperature -10℃-50℃
relative humidity≤90%
Measurement quantities: single impulse voltages
Input voltage: ±20V-±1000V
Input impedance: 1MΩ//30PF
Divider ratio: 0.0-9999.9
Accuracy: <±1%
Rise time: approx. 840nS
Display: LCD
Power supply: 220V±10%
Reference impulse calibrator
The BZF reference impulse calibrator is used for the calibration of impulse measuring system by generating full LI, LIC and SI.
Technical parameters:
Peak value: ±80V to ±1000V
Full LI
Front time: 0.84μS
Time to half value: 60μS
LIC
Chopping time: 0.5--6μS (adjustable)
Full SI
Peak time Tp: 250μS
Time to half value T2: 2500μS
Stability (LI&SI): ±0.5%
Accuracy (LI&SI): ±0.5%
Stability (LIC): ±1.0%