Horizontal end-suction pump
USD $2000 - $2000 /Piece
Min.Order:1 Piece
Product Overview
IHchemical pump is single-stage single-suction (axial suction) cantilevercentrifugal pumps, conveying corrosive liquid with viscosity similar to waterwithout solid particles. Mark, rated performance and size in accordance withinternational standards ISO2858, with characteristics of a wide range ofperformance, high efficiency and easy maintenance, the efficiency of an average5 percent up compared with F-type pump, is the international promotion ofenergy-saving products.
Thetransmission medium temperature of IH chemical pump is -20 ℃ ~ 105 ℃, cantransport medium with a higher temperature with better cooling measurement ifnecessary , suitable for chemical, petroleum, metallurgy, electric power,paper, food, pharmaceutical and synthetic fiber industries, for transport allkinds of corrosive media similar to water without pollution.
Performance range
Flowcapacity 6.3 ~ 400m3/hr;
Head5 ~ 125m;
Speed1450rpm and 2900rpm;
Requiredpower 0.55 ~ 90kw;
Inletdiameter 50 ~ 200mm;
Maximumworking pressure 1.6Mpa;
IHchemical pump has 29 basic types, of which 22 pairs speed (1450rpm, 2900rpm)through A, B with two forms of the impeller diameter cutting variants, reaching112 specifications.
Structural features
IHtype pump is jointly designed product by the whole domestic industry throughadopting the international standard ISO, which are mainly composed of the pumpbody, impeller, seal rings, impeller nuts, pump cover, sealing parts, themiddle frame, axle, suspension components.
Structuralcharacteristics of the pump: pump cover fixed in the middle bracket by the seamallowance and clamp pump cover in the middle by the connection of middle bracketspigot pump case. Pump case is an axial suction and radial discharge, footsupport type, can be directly fixed onto the base. Suspension department isfixed on the intermediate frame by the seam allowance, and supported on a basewith a suspension bracket. To facilitate the demolition, design lengthenedcoupling, without disassembling overhaul inlet and outlet connection piping,pump and motor, just remove the intermediate connector couplings longer, youcan remove the rotor parts for maintenance, which is a common internationalstructure.
Thedirection of rotation of the pump: The pump is directly driven by the couplingby lengthening the motor, clockwise from the motor end.
Pumpshaft seal: mechanical seal and packing seal in the form of pump seal. Packingpump cover is equipped with stuffing, for soft packing seal, the stuffing maypass into a certain pressure of water for seal cooling, lubrication, cleaning; Singlemechanical seal and double mechanical seal two species for mechanical seal, acertain pressure into the seal cavity through the water, rinse the end surfacefriction, while cooling effect. According to demand while allowing the use of asealed cavity adapted to form a predetermined size of ISO3069 other structures,such as mechanical seal with corrugated pipe and expeller seal.