Aluminium SS 3/4 \" AC230V Right Angle Pulse Jet Valve CA20T 010-300
USD $ 35 - $66 /Square Meter
Min.Order:1 Square Meter
Manual Two Component Adhesive Liquid Dispenser Valve For Resin And Epoxy
Automobile Sensor Signal Simulation Tool MST 9000, Automotive Diagnostic Tools for car ECU Repair
Black IP65 H Class Auto Solenoid Valve Coil Landi Reducer Coil 16.3 41.7mm
Solenoid Coil Connector DIN43650B Pneumatic Fittings Junction Box for 22 mm Coil
4mm Orifice Mini Brass Direct Drive 2 Way Pneumatic Solenoid Valve
Goyen diaphragm valve CA20T 010-300 3/4 \" AC230V dust collect right angle pulse jet valve
Description
High performance diaphragm valve with threaded ports. Available with integral pilot or as remotely piloted valve. Outlet at 90° to inlet.
Suitable for
Dust collector applications, in particular for reverse pulse jet filter cleaning including bag filters, cartridge filters, envelope filters, ceramic filters, and sintered metal fibre filters.
Constuction Material:
Body | Aluminium (diecast) |
Ferrule | 304 SS |
Armature | 430FR SS |
Seals | Nitrile or Viton (reinforced) |
Spring | 304 SS |
Screws | 302 SS |
Clip | Mild steel (plated) |
Locknut | Mild steel zinc passivated |
Voltage | DC: 24V, AC: 24V,48V,110V,230V |
Working Temperature | - 20 to + 85 ℃ |
Protection Class | IP65 |
Coil Insulation Class | F |
Working Pressure | 0.35-0.85Mpa |
Diaphragm Seat | PA-6 or Viton coated mild steel or High Density PE |
Sealing & disc | CR (chloroprene) |
Diaphragm | NBR(nitrile/buna-n) or Viton |
Shading coil | Copper |
Connector | DIN43650A |
Weight:
Size | Integral Pilot | Remote Pilot |
(CA) Kg (lbs) | (RCA) Kg (lbs) | |
20 | 0.60 ( 1.31 ) | 0.38 ( 0.83 ) |
25 | 0.73 ( 1.61 ) | 0.51 ( 1.13 ) |
35 | 1.04 ( 2.28 ) | 0.83 ( 1.83 ) |
45 | 1.50 ( 3.30 ) | 1.28 ( 2.83 ) |
50 | 2.89 ( 6.38 ) | 2.68 ( 5.92 ) |
62 | 3.31 ( 7.30 ) | 3.09 ( 6.82 ) |
76 | 4.77 ( 10.52 ) | 4.56 ( 10.04 ) |
INSTAllATION:
1 | For compression fitting types tightness is achieved by the compressed gasket on the blow tube |
2 | Other pipe threads are available on request |
3 | Installation/maintenance instructions are included with each valve |
4 | Spare parts kit and replacement coils are available |
5 | Prepare supply and blowtube pipes to suit valve specification. Avoid installing valves underneath the tank. |
6 | Ensure tank and pipes are free from dirt, rust or other particulate. |
7 | Ensure supply air is clean and dry. |
8 | Mount valves to inlet pipes and blowtube to valves, ensuring no excess thread sealant can enter the valve itself. |
9 | Apply moderate pressure to system and check for installation leaks. |
Maintenance:
Before conducting any maintenance activity on the system ensure that components are fully isolated from
pressure and power supplies. Pressure and power should not be reapplied until the valve has been fully assembled.
Diaphragm and pilot inspection should be conducted annually
DIMENSIONS (mm) :
Product show:
Fitted Repair kits code: Diaphragm K2000 / K2007(Vition)