Stainless Steel Screen Water Meter Strainer With Flat Face PN10 , T Type Filter
Negotiable /Piece
Min.Order:1 Piece
Gray Cast Iron Water Meter Pipeline Strainers With SS304 Screen , JIS 10K Flanged
Cast Steel A216 WCB Y Type Strainer With SS304 Filter , JIS 20K Flange End
Ductile Iron / Stainless Steel Water Pump Foot Valve With SS304 Strainer , Bottom Valve
Hand Lever Operator SS Stainless Steel Foot Valve For Oil , Liquid / Suction Foot Valve
Ball Type Stainless Steel Foot Valve 2 Inch / 4 Inch For Sewage DN15 ~ DN300
Brass / Stainless Steel Foot Valve Thread Connect End , Spring Check Foot Valve
Cast Steel A216 WCB T Strainer With SS304 Screen , T Type Filter
Brief introduction:
The strainer may be used on all types of pipelines to collect granulated foreign substances and
contaminants collected. It can improve the clearance in the medium, and prolong the life of valves
and other equipments. It is suitable for wafer, petroleum and steam.
Mail part & material
Body: gray cast iron, cast iron, ductile iron
Filter: stainless steel
O-ring: NBR
Technical Specification
- Nominal diameter:65~500mm
- Nominal pressure:1.0/1.6/2.5Mpa
FEATURES
• Iron strainers are complete with Flat Face (Series 125YF) or Raised Face (Series 250YF)
flanges in accordance with ASME B16.1.
• Strainer body meets applicable ASME Standard.
• One piece cast body.
• Strainers equipped with bolted cover flange that utilize a flat gasket seal.
• Low pressure drop.
• Upper and lower machined seats.
• 304 SS perforated screens are standard.
• Drain/Blow-off connection furnished with plug as standard.
• Generous screen area and properly proportioned straining chamber to minimize initial pressure
drop while maximizing time between cleanings.
• Compact end to end dimension.
STRAINER INSTALLATION INSTRUCTIONS
A . Ensure all machined surfaces are free of defects and that the inside of the
strainer is free of foreign objects.
B . For horizontal pipelines, the strainer should be installed so that the drain
connection is pointed downwards.
C . For flanged end strainers, the flange bolting should be tightened gradually in
a back and forth clockwise motion.
D . Once installed, increase line pressure gradually and check for leakage around joints
E . If the strainer is supplied with a start-up screen, monitor pressure drop carefully.
SIZE | INCH | 2 | 2½ | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 14 | 16 | 18 |
MM | 50 | 65 | 80 | 100 | 130 | 150 | 200 | 250 | 300 | 350 | 400 | 450 | |
A | INCH | 7.875 | 10 | 10.125 | 12.125 | 15.625 | 18.5 | 21.625 | 25.75 | 30 | 33.25 | 38.75 | 43.12 |
MM | 200 | 254 | 257 | 308 | 397 | 470 | 549 | 654 | 759 | 846 | 984 | 1095 | |
B | INCH | 5.25 | 6.5 | 7.5 | 9 | 13.125 | 15.75 | 18 | 18.5 | 22 | 28.625 | 30 | 31 |
MM | 133 | 165 | 190 | 227 | 335 | 401 | 457 | 471 | 557 | 727 | 762 | 788 | |
C | INCH | 2 | 2.5 | 3 | 4 | 5 | 6 | 8 | 10 | 12 | 14 | 16 | 18 |
MM | 51 | 65 | 76 | 102 | 127 | 152 | 203 | 254 | 305 | 356 | 406 | 457 | |
Weight | kgs | 13 | 16 | 21 | 30 | 43 | 60 | 90 | 140 | 175 | 392 | 627 | 1032 |