Features :
- 12.1 inch super resolution color TFT display
- Maximum 9 waveforms
- Use built-in system, high integrated intelligent module technology, full digital monitoring, super functions, lowest * swearing and low failure rate
- Combined functions of maternal monitor and fetal monitor
- Measure the intrapartum patient and fetal heart rate
- Uterine contraction and fetal movement marker
- Continuous real time recording of fetal heart rate
- Can be switched to normal patient monitoring interface
- 72 hours graphic trends and tabular of all parameters
- 1440 groups of NIBP data storage
- ST analysis
- Anti-high frequency electronic surgical unit and anti-defibrillation, for monitoring in the surgery or for cardiac care
- Use wide-angle, multi-wafer, wide beam and ultrasonic probes
Standard configuration:
- FHR, Uterine Contraction Pressure(TOCO), FM and Maternal ECG, NIBP, SPO2, TEMP, RESP, PULSE, Built-in rechargeable battery, thermal printer
Optional:
Technical Specifications:
Safety |
IEC60601 approved (GB9706) |
Power source |
AC100V-240V, 50/60Hz |
Size |
330mm(L) × 275mm(W) × 160mm(H) |
Net weight |
5.0 kg |
Working |
Temperature: 5 ~ 40℃ Humidity <= 85% |
Transportation and Storage |
Temperature: -20 ~ 55℃ Humidity <= 85% |
Ultrasonic Probe: (Fetal Heart Rate)
Type |
Type B proof, dirctional, using pulse doppler system |
Working frequency |
2.5 MHz |
Transmitting power density |
1.2m W/cm2 |
Probe |
Multi-wafer probe |
Sample rate |
5 ms |
Calculating precision of FHR |
0.25 bpm |
Accuracy of FHR |
1 bpm (100-180 bpm) |
Marker (Fetal Movement)
Manually push button mode |
When pressed, a red strip will be displayed above the FHR graph |
Uterine Contraction Pressure |
Type B proof |
Uterine contraction pressure probe |
Manual zero adjustment |
Design pressure sensitivity: 0-100% |
ECG
Lead |
5 leads (R, L, F, N, C) |
Lead selection |
I, II, III, avR, avL, avF, V |
Waveform |
7 channels |
Gain selection |
×0. 5, ×1, ×2 |
HR and alarm range |
Adult: 15-300bpm Neonate/pediatrics: 15-350bpm |
Accuracy |
±2% or ±2bpm, whichever is greater |
Input impedance |
> 5ΜΩ |
Voltage range of electrode polarization |
±300mV |
Leakage current |
< 30uA |
Filter |
Diagnostic mode: 0.05 ~ 100Hz Monitoring mode: 0.5 ~ 35Hz Surgical mode: 1 ~ 25Hz |
Scaling signal |
1mV ± 3% |
Measurement range |
-1.0mV ~ +1.0mV |
Alarm Range |
-0.80mV~0.80mV |
RESP
Model |
RA-LL impedance |
Measurement range |
Adult: 0 ~ 120bpm Neonate/pediatrics: 1 ~ 150bpm |
Resolution |
1rpm |
Accuracy |
±2rpm |
NIBP
Method |
Automatic oscillometric |
Operation mode |
Auto/Manual |
Alarm Type |
Systolic, Diastolic, Mean |
Measurement ranges |
Systolic BP: 40 ~ 300mmHg Diastolic BP: 10 ~ 220mmHg Mean BP: 20 ~ 240mmHg |
Resolution |
1mmHg |
Accuracy |
Max average error ±5mmHg or ±5%, whichever is greater |
Overload Protection |
Double safety protection |
SPO2
Measurement Range |
0 ~ 100% |
Alarm range |
0 ~ 100% |
Resolution |
1% |
Accuracy |
±2% (80~100%) ±3% (60~79%) |
PULSE RATE
Range |
0 ~ 254bpm |
Resolution |
1bpm |
Accuracy |
±1bpm or ±2%, whichever is greater |
Alarm delay time |
10sec |
TEMP
Channel |
2 channels |
Measurement range |
0~50℃ |
Alarm range |
0~45℃ |
Resolution |
0.1℃ |
Accuracy |
±0.2℃ | |