Electromagnetic Remote Control Detecting X Ray Pipeline Crawler High Imaging Sensitivity
Negotiable /Piece
Min.Order:1 Piece
Non Destructive Testing X Ray Pipeline Crawler Industrial Accurate Positioning
Automatic X Ray Pipeline Crawler , Panoramic Radiation NDT Crawler
Gas NDT Inspection Pipeline Crawler X Ray Machine Long Distance Remote Control
High Precision X Ray Pipeline Crawler , Reliable Magnetic NDT Crawler
Micro Wave Video Pipeline Detecting X Ray Crawler Accurate Positioning
X Ray Robotic Crawler Pipe Inspection Equipment Battery Powered 24mm Penetration
Electromagnetic Remote Control Detecting X Ray Pipeline Crawler High Imaging Sensitivity
Product Characteristic
The X-ray pipeline crawlers include the special part that can detect the welding line of long pipeline. The X-ray pipeline crawlers have the advantages of high radiographic quality, high imaging sensitivity, low failure rate and high work efficiency. The X-ray pipeline crawlers have differential driving and vibration absorbers. The chassis of the X-ray pipeline crawlers can be moved in the pipeline steadily without off center running and overturning. The X-ray pipeline crawlers can be moved in the pipeline with great efficiency because it is controlled by PLC with protecting it from blocking and under voltage. The X-ray pipeline crawler is easy to be separated into several parts and then to be put together, so it is easy to carry. You can change the exposure parameter and make the X-ray pipeline crawler move, stop and have an exposure with the exterior controlling source. The X-ray pipeline crawlers are easy to operate.
Advantages:
X-ray Pipeline Crawler:
1. Accurate positioning;
2. Small size;
3. Excellent imaging quality.
Main performances:
1. Automatic machine training;
2. Exposure when proceed forward and positioning and no exposure during retract;
3.During crawling, HAE-ST-PCcan automatically regulate its speed according to pipe gradient (ascending or descending). Also, it can automatically switch between driving modes according to the gradient (automatically switch between two-wheel driving and four-wheel driving) to realize full-time four-wheel driving;
4. During crawling and exposure process, fault detection functions are available( for water encountering, obstruction, power supply fault, over-current or over-voltage, over-heating of components, under-current, etc.). If any fault is detected, it will immediately retract, to realize realtime protection for the crawler and control it under fault by retracting;
5. External time adjustment: to adjust exposure time outside the pipeline (specific operation method is available in the equipment menu).
Configuration:
1. Creeper body;
2. Lead-acid Batteries;
3. X-ray Generator;
4. Locator;
5. Receiver
X-ray pipeling crawler technical parameters
Applicable pipe size | Φ420—Φ1200mm |
Crawler+flaw detector total length | 1420+740=1160mm |
Total weight | 138KG |
Crawling speed | 20m/min |
Turning radius | 7D |
Positioning error | ±5mm |
Crawling distance | Round trip≥4000m |
Max.crawling slope | 40’’ |
Power | 10 lead-acid battery |
Optional ceramic x-ray tube | XXG-2505H |
X-ray radiation angle | 40×360° panoramic radiation |
Focus size | 1.0×2.0mm |
Exposure time | 12s-5min |
Tube voltage | 4mA |
Figure dimension | 740×260×260 |
X-ray machine weight | 27KG |
Relatively temperature | 90% |
Max.Penetration | ≥34 |
Suitable temperature range | -20℃-60℃ |
Max.penetration acceptance condition | Material A3,focus 600mm,exposure time 5 minutes,double sided lead intensifying foil screen,Tianjing Ⅲ film,dark room operating 20C±2C,developing 5 minutes,black 1.5,sensitivity≤2% |