Delivery Time:30 work days
Certification:TS2232352-2019
Eco Friendly Cloth Dyeing Finishing Machine Liquid Flow and Gas Liquid Mixing
Three with dyeing machine features
This machine can be 1 : 2.5 ~ 1 : 4 low bath ratio to achieve environmental protection energy conservation and emissions reduction condition dyeing process and shorten the cycle of cloth is invalid, achieve ultra-low tension , short process ( due to the in cylinder head , cloth all run in the main cylinder body inner loop , than traditional dyeing machine cycle , than traditional dyeing machine cycle shorten by about 40%, at the same time , fabric and dyeing dyeing efficiency increased by 40% ) .
On the shrinkage force bigger cloth can be used in a flow dyeing , can avoid cloth crepe , edge , increase power and strengthen the style characteristic of cloth .
Good uniform dyeing
No crease
Fabrics can be run under high speed , shorten the cycle time of dyeingStrong airflow mixing dye solution permeate fabric , making the rate of sensitive fabric dyeing reduce to a minimumHigh temperature emissions
High temperature direct emissions and heat recovery systemWhen the water temperature is 130 ℃,it can spray type water to washUnique spray type water system can save more water and shorten the washing time , save energy and cost than that of conventional immersion bath washingTo save energy and cost
Ultra low bath ratio can save a lot of dyes , auxiliaries , water and other energy , reduce operating costs.The newly designed nozzle system can save a lot of energy and ensure that the fabric run smoothly .
wide range of application
Low and constant bath ratio
Bath ratio can be as low as 1 : 2 and 1 : 4
Calculation of The Liquor Ratio
1000kg New Age Air Flow | Full llading | 50% llading |
Types of Fabric | Knitted cotton | Knitted cotton |
Fabric pick up | 2500 ltr | 1250 ltr |
Filter volume | 250 ltr | 250 ltr |
Starting lr | 2750 ltr | 1500 ltr |
Dyes and auxiliaries lr | 500 ltr | 375 ltr |
Final lr | 3250 ltr 1:3.25 | 1875 ltr 1:3.75 |
Specifications
Model | Max capacity | Size(L×W×H) | ||||||
kg | lb | mm | in | mm | in | mm | in | |
HYQD-2-500 | 500 | 1102 | 6050 | 238 | 4900 | 193 | 3600 | 142 |
HYQD-4-1000 | 1000 | 2204 | 8815 | 347 | 4900 | 193 | 3600 | 145 |