Parking System 4S Automatic Barrier Gate With Loop Detector / Photocell
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Wonsun Machinery & Electrical Technology Company
CE / SGS Approved Automatic Barrier Gate 5 Million Operation Times
OEM Manual Realese Automatic Parking Boom Barrier Gate For Airport / Hotel
Automatic Toll Parking System Barrier Gate Operator Straight Arm
Black Highway Automatic Barrier Gate For Vehicle Access Control CE
European Level Design Car Park Barrier Gate With Remote Control Heavy Duty
Access Control AC110 / 220V Electric Barrier Gate For Parking System
Parking System 4S Automatic Barrier Gate With Loop Detector / Photocell
What is the davantages of Wonsun barriers?
1)The humanized clutch device:in case of power off, unlock the clutch device and raise the boom manufally. By the time the power is supplied, lick the clutch device to make it working normally again.
2)Special spring device:Both the compression spring and tension spring can be used in the machine, Using the compression sprin can avoid accidents caused by the tension spring.
3)Three control buttons:for boom raising, falling and pausing.
4)Boom backtrack function:the boom will rise if hits something when falling.
5)Infrared photocell design:for avoiding the crash when the boom falling, so as to prevent the vehicles from being pressed.
6)Both external and internal loop detectors are supported.
7)"open","close" and "stop" controlling interfaces.
8)RS-485 communication serial interface(optional)
9)Traffic light signal connection device: red light for stop,green light for pass.
10)Remote control and wire control for selection.
Model Selection and Differences
Specifications
Model |
WST1211 |
Working Temperature |
-40℃~+75℃ |
Voltage |
220V±10%, 110V±10%, 50/60HZ |
Rated power |
80W |
Relative humidity |
≤90% |
Remote control distance |
≥30m |
Net weight |
48kgs |
Speed |
1S,1.8S,3S, 6S |
Max boom length |
6 meters |
Motor Rotational speed |
1400rmp |
Protection Degree |
IP44 |
1 pcs Gate Barrier
1 pcs arm boom (from 1m to 6m can customised)
1 pcs control panel(built inside)
2 pcs remote controllers
1 pcs manual book
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
3 |
Low working voltage |
Check the voltage and power |
4) Q: When opening/closing,traffic barrier ga