Durable Manual Barrier Gate Arm Barrier For Toll And Parking Lot
Negotiable /Piece
Min.Order:1 Piece
Shenzhen Wonsun Machinery & Electrical Technology Company
Smart Automatic Locking Boom Barrier Gate With Loop Detectoror Vehicle Sensors
Car Parking System Automatic Car Park Barrier and RFID Long Rang Reader
Highway Control Vehicle Barrier Gate With 5 Million Times Open And Close
High Speed RFID Vehicle Barrier Gate For Automatic Car Parking System
2.00mm Cold Rolled Sheet Vehicle Barrier Gate Intelligent Barrier For Car Parking Lot System
High Speed 0.6s Barrier Gate Arm Parking Toll System Controller
Durable Manual Barrier Gate Arm Barrier For Toll And Parking Lot
1 pcs Gate Barrier
1 pcs arm boom (from 1m to 6m can customised)
1 pcs control panel(built inside)
2 pcs remote controllers
1 pcs manual book
Model Selection and Differences
Specifications
Model |
WST1211 |
Working Temperature |
-40℃~+75℃ |
Voltage |
220V±10%, 110V±10%, 50/60HZ |
Rated power |
80W |
Relative humidity |
≤90% |
Remote control distance |
≥30m |
Net weight |
48kgs |
Speed |
1S,1.8S,3S, 6S |
Max boom length |
6 meters |
Motor Rotational speed |
1400rmp |
Protection Degree |
IP44 |
Communication with customers
1) Q: Connected power and press open/close button but traffic barrier gate no action?
A |
Reason |
Solution |
1 |
Fuse blown |
Check fuse and power in controller |
2 |
Battery of remote control powered off |
Change a new one |
3 |
External protection circuit break or at protecting status |
Open the barrier door and click OPEN/CLOSE button on control box |
4 |
Same frequency interference |
Check photocell and loop detector |
2) Q:Connected power and press open/close button,traffic barrier gate will move but even when it is at right position, the motor still running and not stop?
A |
Reason |
Solution |
1 |
Limit switch |
Adjust the horizontal/vertical limit switch to correct position |
2 |
Main controller failure |
Change a new one |
3) Q: Motor running but traffic barrier gate arm no action?
A |
Reason |
Solution |
1 |
Barrier arm at 45° position where is hard to move |
Unlock clutch and manually rotate arm to horizontal or vertical position then try again |
2 |
Tension of balancing spring not suitable |
Adjust spring exactly |
3 |
Low working voltage |
Check the voltage and power |
4) Q: When opening/closing,traffic barrier gate arm cannot reach right position (90° vertical & 180° horizontal)?
A. |
Reason |
Solution |
1 |
Length adjustment of connecting rod not correct |
Open barrier door and unlock clutch to check when arm at 90° vertical position if the master rod covers slave one; when arm at 180° horizontal position if master rod and slave one are in the same straight line |
2 |
Nuts on the limit switch loose |
Tighten the nuts when arm at 90° vertical and 180° horizontal |