1000 Watt 12v 24v 220v Solar Battery Inverter / Psw Inverter With DSP Chip
Brand Name |
One |
Place of Origin |
China |
Model Number |
HI-10224 |
Product Features
Delivery Time:10 work days (According to the order quantity )
Certification:CE FCC
1000watt 12v 24v 220v dc ac Pure Sine Wave Inverter with battery charger
Model : HI-10224
DSP smart chip Core: An individual 64-bit DSP control chip, more text samples and control functions
The detection and control program is written into the DSP chip. The results are fetched by DSP chip and the inverter is controlled by DSP chip. The advantage is that the value is accurate(by effective value). Tolerance is less than 0.01%
Photoelectricity isolation circuitry technology:
Top One: It can detect and modulate the pulse width of boost circuit, reduce the EFT(Electric Fast Transient) and raise anti-interference.
Other: The inverter without this function. Which will cause high EFT(Electric Fast Transient) and low anti-interference.
HI Series Wall-mounting Low Frequency Pure Sine Wave Inverter (220V) |
Model |
HI-351 |
HI-501 |
HI-601 |
HIS-801 |
HI-102 |
HIS-122 |
HI-152 |
HI-202 |
HI-302 |
HI-502 |
Rated Power |
350W |
500W |
600W |
800W |
1KW |
1.2KW |
1.5KW |
2KW |
3KW |
5KW |
Peak Power |
700W |
1000W |
1200W |
1600W |
2KW |
2.4KW |
3KW |
4KW |
6KW |
10KW |
Nominal battery voltage |
12VDC |
12VDC/24VDC |
24VDC/48VDC |
48VDC |
Input |
DC input range |
10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) |
AC Mains input range |
(220/230/240VAC) 140-275VAC |
AC input frequency |
50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) |
Protection |
Low battery alarm |
≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm |
Low battery protection |
≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown |
High battery alarm |
≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm |
High battery protection |
≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown |
Over load protection |
110% more than rated capacity, automatic shutdown |
High temperature |
Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown |
Short circuit protection |
Automatic shutdown |
Output |
Transfer efficiency |
≥87% |
Output voltage |
(DC battery mode) 220/230/240VAC±2% |
Output frequency |
(DC battery mode) 60/50Hz±1% |
Output wave form |
Pure sine wave |
Output voltage |
(AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) |
AVR output stablizer |
AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; |
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; |
The above is for output 220V system reference, 230V/240V output just multiply by percentage |
Output frequency |
(AC mains mode) automatic tracing from AC input |
Other |
Transfer time |
≤8ms |
Display |
LCD Display with function buttons |
Cooling system |
Intelligent cooling fan control system |
≤42℃ slow fan, ≥45℃ fast fan |
AC Charger |
AC charging Voltage |
13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) |
AC charging current |
Steady 15A |
AC over charge protection |
Battery ≧16V (12V) ≧32V (24V) ≧64V (48V), stop charging after 60s alarm |
Working mode
(Optional) |
01 |
AC mains priority |
Always use AC mains as priority input to provide AC output and automatically charge the
Find Similar Products By Category
|