Delivery Time:10 work days (According to the order quantity )
Certification:CE FCC
dc to ac off grid pure sine wave inverter 500w 12V for home supply wall - mounting
Model : HI-50112
Multifunctional operating interface:
a. Adjustable mains priority and inverter priority mode:
Mains priority: When AC mains and DC battery are connected at the same time, inverter chooses AC mains for priority AC output.
b. Inverter priority: When AC mains and DC battery are connected at the same time, inverter converts DC battery power for priority AC output.
Customers can choose mains priority or inverter priority mode according to their own needs, and can switch them at any time.
Switching power is supplied by independent system
It uses a separate power for a single switch chip, which reduces the interference of pulse and make inverter works stably.
HI Series Wall-mounting Low Frequency Pure Sine Wave Inverter (220V) | |||||||||||
Model | HI-351 | HI-501 | HI-601 | HIS-801 | HI-102 | HIS-122 | HI-152 | HI-202 | HI-302 | HI-502 | |
Rated Power | 350W | 500W | 600W | 800W | 1KW | 1.2KW | 1.5KW | 2KW | 3KW | 5KW | |
Peak Power | 700W | 1000W | 1200W | 1600W | 2KW | 2.4KW | 3KW | 4KW | 6KW | 10KW | |
Nominal battery voltage | 12VDC | 12VDC/24VDC | 24VDC/48VDC | 48VDC | |||||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | |||||||||
AC Mains input range | (220/230/240VAC) 140-275VAC | ||||||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz (50Hz/60Hz automatic recognition) | ||||||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | |||||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | ||||||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | ||||||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | ||||||||||
Over load protection | 110% more than rated capacity, automatic shutdown | ||||||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | ||||||||||
Short circuit protection | Automatic shutdown | ||||||||||
Output | Transfer efficiency | ≥87% | |||||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | ||||||||||
Output frequency | (DC battery mode) 60/50Hz±1% | ||||||||||
Output wave form | Pure sine wave | ||||||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | ||||||||||
AVR output stablizer | AC mains<140VAC±5% swtich to DC battery mode, AC mains>150VAC ±5% return to AC mains mode; | ||||||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | |||||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | |||||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | ||||||||||
Other | Transfer time | ≤8ms | |||||||||
Display | LCD Display with function buttons | ||||||||||
Cooling system | Intelligent cooling fan control system | ||||||||||
≤42℃ slow fan, ≥45℃ fast fan | |||||||||||
AC Charger | AC charging Voltage | 13.6-14.2VDC(12V)/27.2-28.4VDC(24V)/54.4-56.8VDC(48V) | |||||||||
AC charging current | Steady 15A | ||||||||||
AC over charge protection | Battery ≧16V (12V) ≧32V (24V) ≧64V (48V), stop charging after 60s alarm | ||||||||||
Working mode (Optional) |
01 | AC mains priority | |||||||||
Always use AC mains as priority input to provid
You May Like
Popular Searches
Wire Wound Resistor
Wire Wound Fusible Resistor
Wire Wound Braking Resistor
light dependent resistor
121 ohm resistor
47 ohm 5 watt resistor
ptc thermistor mz73
wire wound resistors
3 movs
Neutral Earthing Resistor
dump load resistor
5d-13 ntc thermistor
ac shunt
aluminum encased resistor
aluminum encased wirewound resistor
aluminum housed wirewound resistors
Find Similar Products By CategoryYou May Like
|