Delivery Time:10 working days after received your payment
Certification:CE/ROHS/FCC/SGS
High efficiency off grid ups solar inverter dc to ac 1kw solar inverter with CE FCC certification
FI 10212
Quick comparison
Continuous stable output voltage:
Top One:No matter how low or how high the AC input voltage is, with voltage stabilizer our inverter provides standard 110V or 220V stable output, which keeps the loading works stably. Wide stabilizing range of AC input optional.
Others: Only a few inverter in the market has stabilizer technology, even they have, they can only provide short time stabilization but not continuously. So the loading can work in short time stably only but not long time. Or their stabilizing range is not wide as ours.
True Intelligent Cooling Fan
Top One:Dual ball bearing intelligent cooling fan, through built-in realtime temperature monitoring probe it can speed up or slow down according to the working temperature of inverter, in order to reduce the consumption of power. Sand proof design, to keep cooling fan works properly in outdoor environment.
Others: Temperature is detected by circuit NTC(Negative Temperature Coefficient), it can only control the on/off function of cooling fan, which is not true intelligent cooling fan.
LCD HD display:
This series is equipped with high-definition LCD display,
Real-time display the status of machine . Make sure that you can be the first time to know the actual status of the machine.
Model | FI-102 | FI-152 | FI-202 | FI-302 | FI-402 | FI-502 | FI-602 | |
Rated Power | 1KW | 1.5KW | 2KW | 3KW | 4KW | 5KW | 6KW | |
Peak Power | 3KW | 4.5KW | 6KW | 9KW | 12KW | 15KW | 18KW | |
Nominal battery voltage | 12/24VDC | 12/24/48VDC | 24VDC/48VDC | |||||
Input | DC input range | 10.5-15VDC (12V) / 21-30VDC (24V) / 42-60VDC (48V) | ||||||
AC Mains input range | 170-275VAC (220/230/240VAC)±4% | |||||||
AC input frequency | 50Hz: 45-65Hz / 60Hz: 55-65Hz±0.5Hz (50Hz/60Hz automatic recognition) | |||||||
Protection | Low battery alarm | ≤10.5VDC (12V) / ≤21VDC (24V) / ≤42VDC (48V) alarm | ||||||
Low battery protection | ≤10VDC (12V) / ≤20VDC (24V) / ≤40VDC (48V) automatic shutdown | |||||||
High battery alarm | ≥15VDC (12V) / ≥30VDC (24V) / ≥60VDC (48V) alarm | |||||||
High battery protection | ≥17VDC (12V) / ≥34VDC (24V) / ≥68VDC (48V) automatic shutdown | |||||||
Over load protection | 110%<loading<150%, shutdown after 60s alarm, loading>150%, shutdown after 20s alarm | |||||||
High temperature | Built-in temperature real time sensor, ≥85℃ alarm, ≥90℃ automatic shutdown | |||||||
Short circuit protection | Automatic shutdown | |||||||
Output | Transfer efficiency | ≥90% | ||||||
Output voltage | (DC battery mode) 220/230/240VAC±2% | |||||||
Output frequency | (DC battery mode) 60/50Hz±1% | |||||||
Output wave form | Pure sine wave | |||||||
Output voltage | (AC mains mode) stable 220/230/240VAC±10% output (built-in AVR stablizer) | |||||||
AVR output stablizer | AC mains<170VAC±5% swtich to DC battery mode, AC mains>180VAC ±5% return to AC mains mode; | |||||||
AC mains>275VAC±5% swtich to DC battery mode, AC mains<255VAC ±5% return to AC mains mode; | ||||||||
The above is for output 220V system reference, 230V/240V output just multiply by percentage | ||||||||
Output frequency | (AC mains mode) automatic tracing from AC input | |||||||
Other | Transfer time | ≤5ms | ||||||
Display | LCD Display with function buttons | |||||||
Cooling system | Intelligent cooling fan control system | |||||||
≤42℃ slow fan, ≥45℃ fast fan | ||||||||
AC Charger | 7 battery types mode | Gel U.S.A. / Gel European / A.G.M.1 / A.G.M.2 / Sealed lead acid / Open lead acid / Ca