XLPE Insulated, LSZH Sheathed, CWB Screened Instrumentation Cables (Multipair)

XLPE Insulated, LSZH Sheathed, CWB Screened Instrumentation Cables (Multipair)

Negotiable

Min.Order:1

Supply Ability:
0 per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Place of Origin:
China

UNIVERSAL CABLES LIMITED

Business Type: Trading Company
Main Products: Automotive wire , fire resistant cable , instrumentation cable , marine cable , etc.

Product Details

XLPE Insulated,Website: , LSZH sheathed, CWB screened Instrumentation cables (Multipair)RE-2X(c)H 90°c / 300VSTANDARDSBasic design to EN 50288-7APPLICATIONInstrument cable minimizes noise and signal interference, delivering clean signals in harsh environments and general manufacturing operations.These cables are used for transmission of analoge and digital signals in instrument and control systems at chemistry and petr°Chemistry industry plants, power plants, natural gas and petroluem plants, etc...These cables are used in the environments which have no corrosive gases are emitted in the event of fire. In case of fire, these cables inhibit the propagation of the flames whereby the development of smoke is extremely low. Instrumentation cables are not allowed for direct connection to a low impedance sources, e.g. public mains electricity supply. With blue sheath it is suitable for intrinsically safe systems. These cables are not recommended for direct burial. They are for indoor and outdoor installation, in dry and wet l°Cations; on racks, trays, in conduits.FIRE PERFORMANCEFlame Retardance (Single VerticalWire Test)EN 60332-1-2; IEC 60332-1-2; BS EN 60332-1-2; VDE0482-332-1; NBN C 30-004 (cat. F1); NF C32-070-2.1(C2); CEI 20-35/1-2; EN 50265-2-1*; DIN VDE 0482-265-2-1*Reduced Fire Propagation(Vertically-mounted bundled wires& cable test)***EN 60332-3-24 (cat. C); IEC 60332-3-24; BS EN 60332-3-24; VDE 0482-332-3; NBN C 30-004 (cat. F2); NF C32-070-2.2(C1); CEI 20-22/3-4; EN 50266-2-4*; DIN VDE 0482-266-2-4Halogen FreeIEC 60754-1; EN 50267-2-1; DIN VDE 0482-267-2-1; CEI 20-37/2-1 ; BS 6425-1*No Corrosive Gas EmissionIEC 60754-2; EN 50267-2-2; DIN VDE 0482-267-2-2; CEI 20-37/2-2 ; BS 6425-2*Minimum Smoke EmissionIEC 61034-1&2; EN 61034 -1&2; DIN VDE 0482-1034-1&2; CEI 20-37/3-1&2; EN 50268-1&2*; BS 7622-1&2*No Toxic gasesNES 02-713; NF C 20-454Sunlight ResistanceUL 1581 section 1200Oil Resistance**ICEA S-73-532Note: Asterisk * denotes superseded standard, ** denotes Test temperature +60°C, duration 4h. Retention: min 60% of tensile strength/min.60% of elongation, *** denotes optional.VOLTAGE RATING300VCABLE CONSTRUCTIONConductor:Annealed copper solid or plain copper stranded to IEC 60228 Class 2.Insulation:Extruded cross-linked XLPE compound, EN 50290. 2-29.Pair:Two conductors twisted to form a pairLay-up:Pairs laid up in layers of optimum pitchSeparator:Polyester tapeOverall Screen:Tinned copper wire braidOuter sheath:Thermoplastic LSZH compound type LTS3 as per BS 7655-6.1 (Thermosetting LSZH compound type SW2-SW4 as per BS 7655-2.6 can be offered.). UV resistance, hydrocarbon resistance, oil resistance, anti rodent and anti termite properties can be offered as option.COLOUR CODEInsulation:Black / White, continuously numbered on white core(1, 2..)for multipair.Outer Sheath:Black or blue for intrinsically safe systemsPhysical AND THERMAL PROPERTIESTemperature Range During Operation (Fixed State):-30°C – +70°CTemperature Range During Installation (Mobile State):-5°C – +50°CMinimum Bending Radius:7.5 X Overall DiameterCONSTRUCTION PARAMETERSCable CodeRE-2X(C)HNo. of Pairs x2xCross SectionCopperWeightApprox. WeightNo.x2xmm2Kg/kmKg/km0.5mm2, MultipairRE-2X(C)H 2P0.52x2x0.5010.7143RE-2X(C)H 3P0.53x2x0.5011.1159RE-2X(C)H 4P0.54x2x0.5011.9181RE-2X(C)H 6P0.56x2x0.5013.6230RE-2X(C)H 8P0.58x2x0.5014.2264RE-2X(C)H 12P0.512x2x0.5016.4343RE-2X(C)H 16P0.516x2x0.5018.2418RE-2X(C)H 20P0.520x2x0.5019.7487RE-2X(C)H 24P0.524x2x0.5021.15570.75mm2, MultipairRE-2X(C)H 2P0.752x2x0.7511.4160RE-2X(C)H 3P0.753x2x0.7511.9185RE-2X(C)H 4P0.754x2x0.7512.7214RE-2X(C)H 6P0.756x2x0.7514.6278RE-2X(C)H 8P0.758x2x0.7515.4324RE-2X(C)H 12P0.7512x2x0.7517.8427RE-2X(C)H 16P0.7516x2x0.7519.8526RE-2X(C)H 20P0.7520.x2x0.7521.5623RE-2X(C)H 24P0.7524x2x0.7523.17141.0mm2, MultipairRE-2X(C)H 2P1.02x2x1.012.3184RE-2X(C)H 3P1.03x2x1.012.8214RE-2X(C)H 4P1.04x2x1.013.7251RE-2X(C)H 6P1.06x2x1.015.6326RE-2X(C)H 8P1.08x2x1.016.4382RE-2X(C)H 12P1.012x2x1.019.0511RE-2X(C)H 16P1.016x2x1.021.2636RE-2X(C)H 20P1.020.x2x1.023.5775RE-2X(C)H 24P1.024x2x1.025.38921.3mm2, MultipairRE-2X(C)H 2P1.32x2x1.312.9204RE-2X(C)H 3P1.33x2x1.313.5242RE-2X(C)H 4P1.34x2x1.314.5285RE-2X(C)H 6P1.36x2x1.316.7375RE-2X(C)H 8P1.38x2x1.317.4444RE-2X(C)H 12P1.312x2x1.320.2599RE-2X(C)H 16P1.316x2x1.322.6750RE-2X(C)H 20P1.320x2x1.325.1916RE-2X(C)H 24P1.324x2x1.327.01064Note : Other conductor sizes & core configurations are available upon request.Electrical PROPERTIESConductor Area Sizemm 20.50.751.01.31.5Insulation thickness (nominal)mm0.40.40.40.450.45Conductor resistance (20°C)Ω/km36.72518.514.212.3Insulation resistance (20°C)MΩ.km(Min.)5000Mutual Capacitance (1 kHz)pF/m(Max.)≤ 4 pairs115115115120120all other pairs9090909090Capacitance unbalance(1 kHz)pF/500 m (Max.)300L / R (ratio) (max.)μH/Ω2525254040Operating voltage UrmsV300Test VoltageCore to CoreV1500Core to ScreenV1500

Contact Supplier

Ms HelenWong Sales Chat Now
Telephone
86-531-88817113
Mobile
0086-15153183484
Fax
86-531-88819113
Address
1Building, Shuntai Square, High-tech zone, Jinan City, China Shandong Factory high-tech zone, zhang Hangzhou,Zhejiang

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Business Services > Trade Show Services > Trade Show Training
Categories
Hi~