Portable Pulse Oximeter Pediatric Finger Tip Pulse Oximeter For Kid

Portable Pulse Oximeter Pediatric Finger Tip Pulse Oximeter For Kid

Negotiable

Min.Order:1

Supply Ability:
0 per Month
Payment Terms:
T/T L/C D/P D/A
Delivery Detail:
7 days

Quick Details View All >

Brand Name:
Everycom
Place of Origin:
China
Model Number:
EC-P60

Shenzhen Everycom Technology Company Limited

Business Type: Trading Company
Main Products: Digital Blood Pressure Monitors ,Automatic Blood Pressure Monitor ,Arm Blood Pressure Monitor

Product Details

Delivery Time:Within 3days for small quantity; 7~20days for quantity order
Certification:CE

Portable Pulse Oximeter Pediatric Finger Tip Pulse Oximeter For Kids

Product Configuaration:

Function Configuration
Display Red LED
Spo2 parameter measurement Y
Pulse rate parameter measurement Y
Bar graph display Y
Automatic power-off function Y
Low-power UI icon indication Y
Abnormal parameter value alarm function with the measurement value sparkling Sel
Abnormal parameter value alarm function with the sound Sel
Pulse beat sound Sel
Pulse sound On/Off function Y

Attention : \"Y\" expresses the function item is the standard configuration , and the  \"Sel\"  expresses the function item will be configured according to the users’ demand .

1.2 Users : Pediatric , adult.

1.3 Major applications and scope

Is used in measuring the pulse oxygen saturation and pulse rate through finger ; Is fit for family, hospital, oxygen bar, community healthcare, physical care in sports(It can be used before or after doing sports and it is not recommended to use the device during the process of having sport) and etc ; Not recommended to be used for monitoring the patients for a long time without any rest ; Do NOT use the device in an MR/CT environment, in an exprosive atmosphere, or on infant or neonatal patient . High temperature or high pressure steam disinfection for the oximeter is not permitted;Do not have the oximeter immerged in liquid ; Operation of this device below the minimum amplitude of 0.4% modulation may cause inaccurate results The device is designed to measure the percentage of arterial oxygen saturation of functional hemoglobin Factors that may degrade pulse oximeter performance or affect the accuracy of the measurement include the following :

Do not apply the pulse oximiter on the same arm as a blood pressure cuff, arterial catheter or infusion line(s)(IVs) .

Excessive light, such as sunlight or direct home lighting . Moisture in the device

Finger is outside recommended size range

Poor pulse quality

Venous pulsations

Anemia or low hemoglobin concentrations

Cardiogreen and other intravascular dyes

Carboxyhemoglobin

Methemoglobin

Dysfunctional hemoglobin

Artificial nails or fingernail polish .

Appearance

The above picture shows the appearance of EC-P60B , which is composed of main device, light emitter and the light sensor . The main device has such main components : button, OLED screen, battery component , and mechanical device which is divided into two parts .

Screen User Interface

The screen user interface has such information :

Spo2 parameter value and indication icon, 2-digit digital display ; 

Pulse rate and indication icon , 3-digit digital display ;

Bar graph .

 Pulse waveform .

Pulse beat icon .

Battery voltage indication icon .

Technical Specification

3.1 Power

Work voltage : DC 3V( 2 AAA Battery)

Work current : < 30mA

3.2 Screen Disply

Display screen : 0.96\" Dual-color OLED display(blue and yellow)

Screen Resolution : 128*64

Display Mode : four directions display modes can switch through shortly pressing the button under 2 seconds .

3.3 Spo2 Parameter performance

Range : 35~100%

resolution : 1% 

Accuracy(>=70%):

Without disturb or low perfusion :  +-2%

Motion/Light disturb or low perfusion : +-3%

Accuracy(<70%): below 70% unspecified .

3.4 PR Parameter performance

Range : 25~254bpm

resolution : 1 bpm

Accuracy : 

Without disturb or low perfusion : +-2bpm or +-2% , select the larger 

Motion/Light disturb or low perfusion : +-3bpm or +-3% , select the larger

3.5 Blood Perfusion Index performance

Range : 0.2~20%

resolution: 0.1%

3.6 Low Perfusion performance Pi >= 0.4% : Spo2 and PR can be detected correctly ;  Pi < 0.4% : Unspecified.

3.7 Pulse information The pulse waveform, pulse bar graph , pulse beating icon are showed on the screen .

3.8 Pulse sound The pulse beating sound is synchronous with the pulse beating icon sparkling and pulse waveform . Meanwhile the puls

Contact Supplier

Mr. Ckey Tan sale Manager Chat Now
Telephone
86-0755-66607612
Mobile
86-13554715626
Fax
86-0755-23289031
Skype
ckeyalk1
Address
Rm412 & Rm511,Jinma Business Center 3, Mintang Road, Longhua New District Zibo,Shandong

You May Like

New Products

Recommended Products

View More View Less

Find Similar Products By Category

Business Services > Agency Services > General Trade Agents
Categories
Hi~