Tasteless Piping Fm200 Fire Suppression System Pipe Network System
Negotiable /Piece
Min.Order:1 Piece
120L Hfc 227ea Fire Extinguishing System For Independent Zone
Tasteless Fm-200 Fire Suppression Systems Dc24V For Electronic Computer Room
Non-corrosive HFC227ea Fire Suppression System of Cabinet 40L Type
Multiple Zones Network Hfc227ea Fire Suppression System DC24V / 1.6A
Fm200 Direct Type Fire Detection Tube Single Zone Management
Clean Gas Agent HFC227ea Fire Suppression System For Library , Museum
Tasteless Piping Fm200 Fire Suppression System Pipe Network System
Parameter:
No. | specification | Technical Parameter |
1 | Filling pressure | 5.6Mpa |
2 | Scale of Protective region for one zone | area:max single-zone is 800m² volume:max single-zone is 3600m³ |
3 | Spraying time | ≤10s |
4 | Filling density | ≤1080kg/m3 |
5 | power | DC24V/1.6A |
6 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20℃) |
7 | Condition of reserving room for container | temperature: -10~50℃, relative humidity: ≤97% |
8 | max working pressure | 8.0Mpa |
9 | min working pressure | 4.6Mpa |
Applications:
1.Clean gas, colorless and tasteless and non-corrosive
2. Electric insulation, utilization for extinguishing of electrical combustion
3. Totally automatic system
4. Accurate control of protection zone
5. Multiple management in the control of the whole system
6. Agent quantity for biggest zone is enough to protect all zones through selector valves
Competitive Advantage:
In terms of description of agent, one of its competent advantages is that it can be used for all kinds of class fires except metal fire. And it is clean agent. There is no residue and pollution after extinguishing.
Another one is that fm200 extinguishing system is special for critical assets or device. It will have no damage for your property. Relatively, it is cheap and effective to be chosen as fire suppression system.
It is very efficient for you to protect your possession. Since it is a system, it include extinguishing device to put out fire at short time, specially, shorter than 10 second. It means all agent will be discharged in so short time. Then it will be flooding overall. In addition, it has time-delay mechanism. It is around 2 minute. It means when fire happens, there is enough time left to evacuate people from hazardous place.
It can let multiple zones are protectively in the control of one system. Then it will save much money for big and multiple zones
Simulated diagram:
Below attached is one mimic diagram of 5.6Mpa Piping Fm200 Suppression
Composition:
1. Mechanical parts: cylinder with container valve, frame for cylinder group, driving cylinder, frame for driving device, high pressure hose etc. It is mainly used for storing fm200 agent
2. Electrical parts: smoke detector, heat detector, bell etc.
3. Pipe fittings: conduit, connector, elbow, flange etc.