Data Center 90L Network Fm200 Fire Suppression System with Pipeline
Negotiable /Unit
Min.Order:1 Unit
OEM HFC227ea Fire Suppression System Fm 200 Suppression System
Clean Gas Fm 200 Extinguishing System Preparation For Storage Room
40L Double Cabinet Clean Agent Fire Extinguishing System Fm 200
2.5Mpa Fire Suppression System Fm200 120L Single Cabinet Type
Manual / Automatic FM200 Fire Suppression System Of 4.2Mpa 40L Type
Single Cabinet HFC227ea Fire Suppression System For Medical Equipment
Data Center 90L Network Fm200 Fire Suppression System with Pipeline
Description:
1. Clean gas, colorless and tasteless and non-corrosive
2. Electric insulation, utilization for extinguishing of electrical combustion
3. No residue and pollution inside protection zone
4. Short time discharge of extinguishing agent
5. Preparation for storage room
6. Space confirmation of placement for cylinder group
Applications:
Electronic computer room, a data processing center, telecommunications facilities, process control, expensive medical equipment, industrial equipment, library, museum and art gallery, clean room, anechoic chamber, emergency power facilities, flammable liquid storage area, etc.
Compositions:
90L network Fm200 Suppression with pipeline is mainly composed by three parts. Extinguishing devices and pipe fittings and electrical accessories.
Extinguishing devices are such things, like cylinder to fill and store fm200, frame and driving device(nitrogen cylinder) to trigger the storage cylinder to discharge agent and so on.
Pipe fittings are those conduits to connect extinguishing device and guide agent into protective zone, like high pressure galvanized steel pipe and flange and elbow and so on.
Electrical accessories are those things which are used to detect and monitor whole protective area and control whole system, also warn people to evacuate and prevent from fire expansion.
These integrated three parts will be efficient to detect and supervise and alarm and extinguish fire automatically.
Here attached below is complete composition of whole system,
Parameter:
No. | specification | Technical Parameter | |
1 | Filling pressure | 4.2Mpa | 5.6Mpa |
2 | Scale of Protective region for one zone | area:max single-zone is 800m2 volume:max single-zone is 3600m3 | |
3 | Spraying time | ≤10s | |
4 | Filling density | ≤950kg/m3 | ≤1080kg/m3 |
5 | power | DC24V/1.6A | |
6 | Nitrogen Pressure of Driving Device | 6.0±1.0Mpa(20℃) | |
7 | Condition of reserving room for container | temperature: -10~50℃, relative humidity: ≤97% | |
8 | max working pressure | 5.3Mpa | 8.0Mpa |
9 | min working pressure | 4.2Mpa | 4.6Mpa |