Co2 Ndir Sensor With 3 Led Indicators , Co2 Detectors For Homes
USD $4 - $5
Min.Order:1
Tongdy Control Technology Co., Ltd
Adown Probe Waterproof CO2 Transmitter / Transducer Carbon Dioxide Sensor HVAC
Semiconductor Carbon Monoxide Sensor With LCD Display And Relay
Plug And Play Temperature And Humidity Controller With Max 16a Relay Output
Relay Output Digital Co2 Controller Grow Room 3 LED indicators
Indoor Air Quality Detector VOC Monitor / Meter / Sensors / TesterWith Relay Output
VOC Gas Detector / VOC Gas Detector / Co2 Sensors For Ventilation
Gas detected |
Carbon Dioxide (CO2) |
Sensing element |
Non-Depressive Infrared Detector (NDIR) |
Temperature sensor |
NTC |
Temperature correction |
Self compensation |
CO2 NDIR life |
15 years |
Consumption |
3.5W/ Max, 2.5W/ Average |
Accuracy@25℃(77℉) |
±40ppm + 3% of reading |
Stability |
<2% of FS over life of sensor (15 yr typical) |
Warm up time |
2 hours (first time) 2 minutes (operation) |
CO2 measuring range |
0~5,000ppm(default ), 0~2,000ppm programmable selection |
CO2 setting & Display resolution |
1ppm |
Temperature measuring range |
0~50℃(32~122℉) |
Temperature setting range |
5~45℃(41~113℉) |
Option: 1X dry contact output |
Rated currency for contact point: 2A 220VAC/30VDC, resistance load |
Option: RS485 communication interface |
9600/14400/19200(default)/28800/38400bps rates selectable by program,15KV protection for static, independent address setting |
Operation condition |
0~50℃ (32~122℉), 0~95%RH without condensing |
Power supply |
220VAC/110VAC or 24VAC 50/60HZ±10% |
Weight |
380g |
Dimensions |
130mm×90mm×40mm |
Connections Interface |
Locate in interface of connection |
Installment standard |
65mm×65mm or 2”×4” wire box |
Wiring standard |
Wire section area<1.5mm2 |
Approval Standard |
CE-Approval |
Programming and selection |
DIP switches inside and external push-buttons |
Features
Wall moutn CO2, Temp. & RH monitor/controller NDIR CO2 sensor technology of infrared self diffusion, 15 years lifetime LCD display CO2, Temp. & RH real time measuring value 3 LEDs indicate CO2 level to remind people, LED’s brightness adjustment With buttons to adjust setpoint of relay One relay on/off output optional to control ventilator or CO2 generator 1X 0~10VDC optional Modbus RS485 interface optional USB data logger optional 0~5000ppm default, 0~20000ppm selectable 24VAC/VDC, 100/120V, 220/240V selectableApplication
Hotel, exhibition hall, hospital, shop, restaurant, air port, train station, theater and other public places
House, villa, office, meeting room, classroom and other places
Greenhouse, mushroom, grown room and other agricultural applications
All ventilation systems
Buttons and LCD
Mounting and dimensions
Wiring Diagram
Model Guide
Note: X2 + X3 ≤1