Mini X-ray tubes for high frequency dental X ray equipment , KL27-0.8-70,
Negotiable /Piece
Min.Order:1 Piece
Stationary Anode Diagnostic / Treatment Dental X-ray Tube Equivalent To TOSHIBA D-054 X-ray Tube
Durable Diagnostic Dental X-ray Tube for Dental Equipment / X ray film machine 85kV
Mini Medical X-ray Tubes / Tungsten X ray tube for Portable Radiographic X-ray Unit , C-ARM
30kJ Durable TOSHIBA Replacement Medical X-ray Tubes for C Arm X-ray machine
High Vacuum Glass Medical X-ray Tubes ReplacementTOSHIBAX-raytube for Portable X-ray Unit
Digital Medical X-ray Tubes , X raymachinetube For Bone Mineral Densitometer X-ray System
Mini X-ray tubes for high frequency dental X ray equipment , KL27-0.8-70
Quick Detail:
Type:Station anode x-ray tube
Application: For intra-oral dental x-ray unit
Model: KL27-0.8-70
Equivalent to CEI OX70-M
Integrated high quality glass tube
Description:
KL27-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit. KL27-0.8-70 tube has one focus.
The integrated high quality tube with glass design has one super imposed focal spot and a
reinforced anode. The high anode heat storage capacity ensures a wide range of applications for intra-oral dental application. A special designed anode enables an elevated heat dissipation rate which leads to a higher patient throughput and a longer product life. A constant high dose yield during the entire tube life is ensured by the high density tungsten target. Ease of integration into system products is facilitated by extensive technical support.
Applications:
KL27-0.8-70 Stationary anode X-Ray Tube is especially designed for intra-oral dental x-ray unit and available for a nominal tube voltage with self-rectified circuit.
Specifications:
Nominal Tube Voltage………………………………………….…...……………………....70kV
Nominal Inverse Voltage…………..…………………….………………..…………………85kV
Nominal Input Power(at 1.0s)………………………………………………………………840W
Max. Current Continuous Service……………………………….………………….2mA x 70kV
Max. Anode Cooling Rate……………………………………….………….………………140W
Max. Anode Heat Content………….……….…………………..……………………...……..7kJ
Filament Characteristics………………………..….….………………..Ifmax 2.1A,2.85±0.5V
Nominal Focal Spot………………………………………………………..0.8 (IEC60336/2005)
Target Angle………………………………………………………….……………………….19°
Target Material…………………………………..………………….…………………Tungsten
Cathode type……………………….…………………………………………….…….W filament
Permanent Filtration………..…………..……………...Min. 0.5mmAl/50 kV(IEC60522/1999)
Dimensions………………………………..…………….……72mm length by 30mm diameter
Weight…………………………………………………………………………….……..90 grams
Competitive Advantage:
Elevated anode heat storage capacity and cooling
Constant high dose yield
Excellent lifetime