Portable Digtal Ultrasonic Flaw Detection Test with Big memory of 500 A graph
Negotiable /Piece
Min.Order:1 Piece
Basic Type Coating Thckness Gauge for Car Industry with Magnetic Induction
4 Digits LCD Painting Coating Thickness Gauge , TG-8010 thickness checking gauge
Good stability Eddy current 0.1um / 1um Coating Thickness Tester TG8830N , 1250 micron
Wet Film GB 0 - 150um Coating Thickness Tester Gauge for oil - painting , dope
Portable Coating Thickness Gauge Cross Hatch Cutter , digital thickness gauge
Electronic Film Thickness GaugeTG-2100 2000 Micron Coating With Separate Probe
Portable High Resolution Digtal Ultrasonic Flaw Detectors A Scan FD510 with Big memory of 500 A graph
Main faetures:
★ Automated calibration,Automated gain, 0-110dB gain
★ DAC,AVG,TCG,B scan,AWS
★ High-speed capture and very low noise
★ Solid metal housing,water / oil proof,dust proof
★ high contrast viewing of the waveform from bright
★ Powerful pc software and reports can be export to excel
Automated display precise flaw location(Depth d,level p,distance s,amplitude,sz dB,ф); Automated switch three staff gauge ((Depth d,level p,distance s); Automated calibration of transducer Zero-point, Angles, Front edge and material Velocity ; Convenient to make and use DACTCG and AVG to evaluate the echo, the curve can be modified and compensated 6dB DAC functions; 100 independence setup, any criterion can be input freely, we can work in the scene without test block; Big memory of 500 A graph Automated gain and gain scan; Peak Hold and Peak Memory; B scan; AWS D1.1 Automated make video of test process and play; use upan,the length of video is unlimited. Powerful pc software and reports can be export to excel; Li battery, continue working time up to 9 hours; The embeded software can be online updated;Other assistant function
Display freeze; Automated echo degree; Angles and K-value; Lock and unlock function of system parameters; Electronic clock calendar ; Two gates setting and alarm indication; Gate and DAC alarm;Title |
Parameter |
Title |
Parameter |
Measuring Range(mm) |
0 ~ 6000 |
Measurement Mode |
Single,Dual,Thru |
Vertical Linearity Error |
≤3% |
Reject |
0~80% |
Horizontal Linearity Error |
≤0.1% |
Pulse Displacement(μs) |
-20 ~ +3400 |
Sensitivity Leavings |
≥62dB |
Zero(μs) |
0.0 ~ 99.99 |
Dynamic range |
≥32dB |
Port Type |
BNC(Q9) |
Resolving Power |
≥36dB |
Operating Temperature (℃) |
-20~50 |
Frequency Range(MHz) |
0.5 ~ 15 |
H×W×D(mm) |
240×156×48 |
Gain(dB) |
0 ~ 110 |
Weight(kg) |
1.0(with battery) |
Material Velocity(m/s) |
1000 ~ 15000 |
Standard Delivery:
Main unit
2.5MHZ-ф20 straight probe
4MHZ-8x9mm, 60degree angle probe
4A/9Vpower adapter
Probe connection cable (BNC to BNC)
Probe connection cable (BNC to Lemo 00)
Instruction manual
Carrying case
RS232-USB converter
Additional Accessories:
Data managing software
Data managing cables RS232
Straight probe (5MHZ-ф20)
Straight probe (2.5MHZ-ф20)
Straight probe (2.25MHZ-ф20)
Straight probe (1MHZ-ф20)
Angle probe (4MHZ-45degree, 8*9mm)
Angle probe (4MHZ-60degree, 8*9mm)
Angle probe (4MHZ-70degree, 8*9mm)
Angle probe (4MHZ-80degree, 8*9mm)
Angle probe (2MHZ-45degree, 8*9mm)
Angle probe (2MHZ-60degree, 8*9mm)
Angle probe (2MHZ-70degree, 8*9mm)
Angle probe (2MHZ-80degree, 8*9mm)
Probe T/R (5MHz-ф20mm, focus 15mm)
Probe T/R (2.5MHz-ф20mm, focus 15mm)
Connection cable to probe (BNC-BNC)
Connection cable to probe (BNC-Lemo 00)
Connection cable to probe (BNC-Lemo 01)
Connection cable to probe (Lemo 00-Lemo 01)
Lithi