WT Series Prevent bedsores Air mattress bed
Negotiable /Pair
Min.Order:1 Pair
B.WT102A PU-Luxurious type
Technical Specifications
The Power Unit Specification:
1) Input : AC220V, 50Hz OR AC110V, 60Hz
2) Input Power: 12W (Low power consumption)
3) Weight: 1.0Kg (approx)
4) Dimension: L25cm * W15cm * H8cm
5) Air flow rate: 7 liter per min, 15 liter per min
6) Alternating cycle time 5-6 min/pre
7) Regulating range of pressure: WT101A(50-110mmhg); WT102A(40-90mmhg)
The Bubble Pad Specification:
Standard State:
1) Material: PVC(Mildew proof material)---WT101A PU---WT102A
2) Dimension: L200cm * W90cm * H5cm---WT101A L190cm * W90cm * H10cm---WT102A
3) Weight: 2Kg (approx.)
Temperature & Humidity Limited:
1) Operating Temperature: 5 to 45 Celsius degree (41 to 113 degree Fahrenheit)
2) Transportation Temperature: -10 to 45Celsius degree (14 to 113 degree Fahrenheit)
3) Transportation Humidity: 5 to 95 percent
Storage Environment
1) Storage Temperature: 5~ 45 Celsius degree
2) Storage Humidity: 10 to 80 percent
Product Functions
Purpose: The product is for the purpose of aiding the prevention of pressure ulcers and effective treatment of patients.
Pressure ulcers are commonly known as bedsores. They occur when there is damage caused by pressure (or shear) or friction to the skin, or even the underlying tissues, muscles and bones. Pressure ulcers are a common problem of patients suffering from long-term physical immobility including those who are inflicted with spinal cord injury, bedridden for a long-term, not clearly conscious, inflicted with bladder or bowel incontinence, diabetes, skin fragility, physical weakness or malnutrition. It is an extremely complex task to treat pressure ulcers once they occur.
In a minor case, the wounds take weeks to heal. In a severe case, sepsis, amputation or death may occur. This not only damages health, but also is a burden to and waste of medical resources. Using the bubble pad can aid the prevention of pressure ulcers and effective treatment of patients.
The bubble pad can be placed on the overlay of a standard medical bed. The bubble pad can be alternately inflated and deflated with two rows of coupled air hoses that are connected to the power unit and activated in the Alternating Pressure Mode.
Theory of Alternating Pressure Mode: This process allows effective arrangement in a way that a single area of the body remains in a completely pressure free and lifted state for a fixed period. This allows body tissues to be temporarily relieved of pressure and blood to circulate smoothly around the tissues. This in turn heals, improves and prevents the occurrence of pressure ulcers.