Product Details
RScan CFD-3033 CAR SCANNER
RScan CFD-3033 Standard Features
200 kv x-ray imaging
Drive-through scanning of occupied vehicles
Radiation safe for vehicle occupants,Website: , bystanders and operators
2.8 m (W) x 3.0 m (H) recommended scan size
Industry leading X-ray imaging quality
New scan control system to ensure constant image quality Independent of drive through speed
Easy-to-use RScan Cargo Viewer software
Operating environment range supports worldwide deployment
Easy to maintain
Cold and/or hot weather package for expanded operational environment
High Z / Low Z material separation option
Inspection office with amenities
Electronic data interface and networking
Physical Specifications
Physical Specifications
Platform Type Car / Vehicle scanner
Platform Drive Through Portal structure with fiberglass skin
View Direction Side shooter
Overall Dimensions Depth: 2.0 m, Width: 4.6 m, Height: 4.2 m
Scan Area Dimensions Width: 3.0 m, Height: 3.3 m
Recommended Maximum Vehicle / Object Scan Size Width: 2.8 m, Height: 3.0 m, Length: Unlimited
Minimum Scan Height 0.25 m from ground
Scan Orientation 90° inspected object
Operation
Set-up 10 minutes in standard operating environment
Crew 1-2 inspectors and optional ground marshal Further inspectors for increased throughput
Scan Mode Portal drive-through scan mode only Occupied vehicle - bumper to bumper
Scan Direction Single direction (standard)
Scanning Speed 10-15 km/h
X-Ray Generator and Image Performance
Energy 200 Kv x-ray tube
Steel Penetration 30mm
Wire Resolution in Air 1mm
Contrast Resolution (Behind 10 mm) % 10%
Material Separation (option) 2 level - low z/high z
Operating Environment
Operational Temperature (at Sea Level)
-10 to +40
-40 with optional cold weather package
+55 with optional hot weather package
Relative Humidity 5 to 95% non-condensing
Maximum Baseline Wind Speed 40 km/hour
Radiation Safety
Open Radiation Exclusion Zone Length: 8 m x Width: 8 m
Radiation Dose at Exclusion Zone Boundary in One Hour
1 μSv/hour for scanning 50 vehicles
Radiation Dose to Occupants less than 0.25 μSv
Radiation Dose to Crew in One Hour 0.5 μSv/hour
Radiation Dose to Cargo per Scan less than 0.25 μSv
Shielding Type Not required
Shanghai Rays reserve the right to change the parameters according to the actual requirements without notice.