Product Details
Basic Info.Model NO.:12FT150Type:Lead-Acid BatteriesUsage:UPS,Website: , TelecomNominal Voltage:12VShape:Square BatteryRechargeable:ChargeablePackage:Carton Box and Pallet PackingSpecification:CE, ULTrademark:CSPOWEROrigin:ChinaSealed Type:SealedMaintenance Type:FreeSize:288X288X551X110(Mm)Weight:Approx48.0kg(105.82ibs)Max Charge Curent:37.5AMAV Discharge Current:500A(5 Sec)Color:Dark Grey or BlackBattery Type:Lead Acid BatteyCertificate:UL, CE, ISO 9001:2000, ISO 14001:2004, SA8000OEM:YesHS Code:8507200000Production Capacity:50 Containers Per MonthProduct DescriptionAGM Battery 12V150AH Deep Cycle Front Terminal AGM Battery for UPSPackaging & DeliveryPackaging Detail: Each unit in one cartonDelivery Detail: 15~20 days upon receipt the official order. Specifications* CSPOWER UPS Battery* Valve Regulated Lead Acid Battery* General Gel Battery* Front Terminal AGM Battery* Deep Cycle AGM Battery"12FT-150/12FT-150FR" (Front Access )Sealed Gas Recombinaiton Technologgy is specially designedFor Telecom and UPS applications. Features and Banefits: 1)10 years design life2)Flame Retardant Poly Propylene Case and Cover* Impact resistance, self-extinguishing material with standard underwriters laboratories (UL)94V rating3)Tank Formed Plate Construction* 100% capacity on shipment* Plate consistency and matching dependable performance4)Copper Threaded Insert Post* High conductivity* Retains required torque values and allows for easy installation5)Epoxy Post Seal* Elimination of acid egress for trouble -free service life6)Ceramic Disc Flame Arrestor* Prevent any errant spark or flames from entering the battery7)Transporation* Non-hazardous for air/sea/rali/road transportation8)Applicable Stanards* UL Recognized* UL1778 4th edition-UPS eqipment certification* IEC 60896 Part 21-VRLA methods of testing* IEC 60896 Part 22-VRLA requirements* BS 6290 Part 4- specifications for VRLA classification9) CSPOWER Manufacturing* ISO 9001 Quality Manufacture System* ISO 14002 Environment Mangment System* OHSAS 18001 Workplace Safety & HealthApplied Scope: * Telecom* UPS applicationUse and maintenance1)Please use constant-voltage charge. 2)Please do tighten the bolts to avoid sparkle and poor contact when the battery is in use3)Please do not use it near the heat source and open flame4)Please keep it at low temperature. Please change it while there is liquid leaking or Specification
NOMINAL VOLTAGE
:12V
NOMINAL CAPACITY
:150Ah@8hr.rate to 1.75 v/cell
DIMENSIONS
TOTAL HEIGHT
CONTAINER HEIGHT
LENGHT
WIDTH
:288mm(11.34 inches)
:288mm(11.34 inches)
:551mm(21.69inches)
:110mm(4.33 inches)
WEIGHT
:APPROX48.0Kg(105.82 Ibs)
CONTAINER MATERIAL
(FLAME RETARDANT)
:UL94HB ABS
:UL94V-0 ABS
INTERNAL RESISTANCE(25°C,77.F)
:~4.0M
DISCHARGE CAPACITY UNDER DIFFERENT TEMPERATURES
40°C :~102%
20°C :~100%
0°C :~85%
Characteristics
CAPACITY 25°C/77.F
20hr@2.86A
10hr@5.5A
3hr@14.8A
1hr@36A
:160Ah
:150Ah
:116Ah
:93Ah
CHARGE VOLITAGE 25°C/77.F
STANDBY USE :13.65V±0.15V
CYCLE USE :14.7V±0.3V
MAX DISCHARGE CURRENT
:500A(5sec)
MAX CHARGE CURRENT
:37.5A
SELF-DISCHAREG RESIDUAL CAPACITY(25°C,77.F)
AFTER 3 MONTHS :~90%
AFTER 6 MONTHS :~82%
AFTER 12 MONTHS :~70%
Cycle Life(25°C,77.F)
30%DOD :>1800TIMES
50%DOD :>800TEMS
100%DOD :>350TEMS