Product Description
Hiconics HID600A Series High Performance Vector Control VFD could meet almost all the demands of the current fields like high performance, high reliability, high flexibility and high expansibility, etc. It could be widely used in the speed control of AC asynchronous motor, permanent magnet synchronous motor and spindle motor. With many advanced functions and special design adopted, this kind of VFD could offer solution according to current situation of clients with lower cost.
Application Field
1. Mining Used Machinery
2. Metal Processing Machinery
3. Textile Machinery
4. Oil Pump Used Machinery
5. Construction
6. Rubber Processing Machinery
7. Injection Molding Machinery
8. Crane Hoist Machinery
Function Features
1. Permanent Magnet synchronous Open Loop Vector Control Adopted
Open loop vector control method is adopted in the controlling of permanent magnet synchronous motor to reduce faults in site with simple wiring connection and high precise of speed control.
2. Superior Responsiveness
Vector variable frequency controlling technology could achieve superior dynamic responsiveness. This function could make sure the VFD responds to the set speed quickly and the system follows the change of load immediately, thus increasing operating efficiency of the system.
3. Perfect Over-Current/Over-Voltage Prevention Function
With perfect transient current/voltage controlling capacity, the machine could ensure a relatively stable operation of system without sudden trip during fast accelerating or decelerating of speed or load fluctuation.
4. Background Monitoring Software Adopted
The oscilloscope function of background monitoring software could observe the real-time running state of VFD efficiently, which is convenient to debug on site.
5. Parameter Copy Function of Keyboard
The set parameter could be copied through the keyboard and uploaded or downloaded to the same model of VFD, which could simplify parameter setting operation.
6. Overmodulation Function
Compared with traditional sinusoidal modulation, PWM Overmodulation function could improve use ratio of bus voltage and increase output power of VFD. It could be used in the environment of low power grid voltage, long-term overload or impact load.
7. Rich Control Method
1. VC control method: suitable for high precise of speed control occasion
2. SVC control method: suitable for asynchronous motor, variable frequency motor
3. V/F control method: suitable for the occasion of variable frequency drive with many motors
8. Various Braking Method
1. Decelerating DC braking: could realize a fast and stable stop with high precise, suitable for cranes, mining used hoist.
2. Starting-up DC Braking: suitable for occasions of braking motor before starting-up action in order to remove irregular rotation caused by external factors, like large-size fan.
3. Dynamic Braking: suitable for 0.75-15kw built-in braking units of all sizes. When a fast stop of machine is needed, braking resistor could be directly connected. This braking method could be used in frequent braking occasion of high inertia load.
4. Magnetic Flux Braking: Its working principle is to turn kinetic energy into thermal energy and consume the thermal energy in the rotor of motor. This function could effectively restrain the increase of bus voltage during braking process. This method is suitable for fast stop of machine of infrequent start-up or stop of high inertia load.